12
EXPERT LA rev.00
EXPERT LA
•
Back
Press BACK to return to the previous menu.
•
Main LCD Screen
The large LCD screen is used to display the
various parameters and menus. The contrast
of the screen can be adjusted using the po-
tentiometer located behind the display. Open
the front panel to access the potentiometer.
•
LED Display
This display shows the current reading of
chosen sensor(s). Refer to section 4.5 to
select what information needs to be shown
on the LED display.
•
Status Leds
Status pilot lights indicate the current sta-
tus of the outputs. Refer to section 3.4 for
further information about these LEDs.
•
Backlight button
Press this button to light up the LCD screen.
3.2
Parameter Adjustment
Use navigation buttons to select the desired pa-
rameter on the main screen. A parameter that
can be modified blinks when it is selected; non-
blinking parameters cannot be changed.
-
+
LCD CONTRAST
POTENTIOMETER
Backlight
Button
3.3
Language Selection
The user interface of the controller can be displayed
in multiple languages. Follow these steps to change
the language selection:
Select:
Main menu
More, Otros or Outros
English, Español or Português
•
The controller automatically changes the lan-
guage display.
Press and hold the main menu
button for 5 seconds to switch
the language selection.
Main menu
Monitoring
Program
Selection
Setup
Time/Date
Español
Português
User Settings
Use to navigate
81
EXPERT LA rev.00
EXPERT LA
15.1 Relay Assignment Template
PROGRAM 1
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Heater 4 Hi Fire
Heater 4
Heater 3 Hi Fire
Heater 3
Heater 2 Hi Fire
Heater 2
Heater 1 Hi Fire
Heater 1
Min. vent. on/off fans
Fan stage 1
Fan stage 2
Fan stage 3
Fan stage 4
Fan stage 5
Fan stage 6
Fan stage 7
Fan stage 8
Fan stage 9
Fan stage 10
Fan stage 11
Fan stage 12
Tunnel door 1
OPN
Tunnel door 1
CLO
Tunnel door 2
OPN
Tunnel door 2
CLO
Inlet 1 / Vent door 1
OPN
Inlet 1 / Vent door 1
CLO
Inlet 2 / Vent door 2
OPN
Inlet 2 / Vent door 2
CLO
Natural curtain 1
OPN
Natural curtain 1
CLO
Natural curtain 2
OPN
Natural curtain 2
CLO
Feeder relay
Backup relay
Misting
Cool cell
Time Clock 1
Time Clock 2
On/Off Lights
Output #: