PROGRAM2
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Heater 4 Hi Fire
Heater 4
Heater 3 Hi Fire
Heater 3
Heater 2 Hi Fire
Heater 2
Heater 1 Hi Fire
Heater 1
Min. vent. on/off fans
Fan stage 1
Fan stage 2
Fan stage 3
Fan stage 4
Fan stage 5
Fan stage 6
Fan stage 7
Fan stage 8
Fan stage 9
Fan stage 10
Fan stage 11
Fan stage 12
Tunnel door 1
OPN
Tunnel door 1
CLO
Tunnel door 2
OPN
Tunnel door 2
CLO
Inlet 1 / Vent door 1
OPN
Inlet 1 / Vent door 1
CLO
Inlet 2 / Vent door 2
OPN
Inlet 2 / Vent door 2
CLO
Natural curtain 1
OPN
Natural curtain 1
CLO
Natural curtain 2
OPN
Natural curtain 2
CLO
Feeder relay
Backup relay
Misting
Cool cell
Time Clock 1
Time Clock 2
On/Off Lights
Output #:
11
EXPERT LA rev.00
EXPERT LA
3.
USER INTERFACE
3.1
Location of the Controls
•
Menu selectors
Use these buttons to select a menu.
•
Main menu short-cut key
This short-cut key provides access to the
main menu and allows seeing the current sta-
tus of each input and output on the main
screen. The main menu is automatically se-
lected after 4 minutes of inactivity.
Main
Screen
Menu
Selectors
Menus
LED
Display
Navigation
Buttons
Adjustment
Buttons
Status
LEDs
Main menu
short-cut key
Back
Page-
up
Page-
down
Main Menu
Alarm
Clean Mode
Light
Open
Close
Open
Close
Open
Close
Open
Close
Open
Close
Open
Close
12
11
10
9
8
7
6
5
4
3
2
1
Min. Vent.
1
2
3
4
Misting
Cool cell
0-10V
Clock 1
Clock 2
Tunnel 2
Tunnel 1
Curtain 2
Curtain 1
Vent Door/
Inlet 2
Vent Door/
Inlet 1
S
ta
ge
s
H
ea
te
rs
Back
Page-
up
Page-
down
Adjust
•
Navigation buttons
Use these buttons to select an item displayed
in the main screen. In addition, the left and
right-arrow key are also used to move
through the display by pages (left = page-
up, right = page-down).
•
Adjustment buttons
Use these buttons (+ or -) to modify the