EXPERT LA rev.00
EXPERT LA
MAIN FEATURES:
VERY LARGE LCD DISPLAY
A large LCD screen provides an efficient interface
for displaying, monitoring and adjusting the param-
eters.
3 CONTROLLER PROGRAMS
The controller allows using 3 different programs to
control the room temperature. It is thus possible to
activate a specific program, that uses particular
temperature settings, in accordance with the ani-
mal age for instance.
STATUS LEDS
Pilot lights that indicate the status of the control-
ler outputs are located on the faceplate of the con-
troller. These LEDs allow monitoring the system’s
operation without having to enter the building.
MINIMUM VENTILATION CYCLE
When ventilation is not required to reduce the room
temperature, fan outputs can run either continu-
ously or intermittently to reduce humidity levels
and supply oxygen to the room.
8 INDOOR TEMPERATURE SENSORS
Up to eight temperature sensors can be connected
to the controller to obtain an accurate reading of
the average room temperature and a faster reac-
tion time.
NATURAL VENTILATION CURTAINS
The controller can open 2 natural ventilation cur-
tains and stop all ventilation when the outside tem-
perature is sufficiently warm.
TUNNEL VENTILATION
When the room temperature rises, tunnel ventila-
tion reduces the actual temperature perceived by
the animals.
HUMIDITY CONTROL
The inside and outside relative humidity sensors al-
low controlling humidity levels in the room.
0-10V OUTPUT
The controller has 2 internal 0-10V outputs. The
first 0-10V output can either be used to control an
air inlet or variable-speed fans and the second out-
put can control lighting equipment.
CONTROL OF THE AIR INLET MOVEMENT
The movement of vent doors (inlets) can be coordi-
nated with the operation of the fans. This allows
the vent doors (inlets) to be adjusted correctly,
without the influence of uncontrollable factors such
as wind or air from adjoining rooms
HISTORY MENUS
History menus allow monitoring the sensor read-
ings and verify the run time of some outputs. The
controller comes with the following histories menus:
•
Minimum and maximum sensor readings:
Ambient temperature ........... 60 days
Inside temperature sensors .... 10 days
Outside temperature sensor ... 75 days
Inside humidity sensor ........... 75 days
Outside humidity sensor ........ 75 days
Static pressure sensor ........... 75 days
•
Run time of each heater ........
75 days
•
Run time of each feeder ........
75 days
•
Daily water consumption .......
75 days
ALARM MANAGEMENT
The controller provides alarms for high-low tem-
peratures, defective sensors and other system fail-
ures. It keeps in memory the 20 most recent alarm
conditions.
PASSWORD PROTECTION
A password can be enabled to restrict access to
the setup functions of the controller.
Program 1
Program 2
Program 3
# feeders
____ (0-4)
____ (0-4)
____ (0-4)
# heating stages
____ (0-4)
____ (0-4)
____ (0-4)
Use Heater Lo/Hi Fire?
(Common to
all pro grams)
# fan stages
____ (0-12)
____ (0-12)
____ (0-12)
# clock output
____ (0-2)
____ (0-2)
____ (0-2)
# natural vent. curtains
____ (0-2)
____ (0-2)
____ (0-2)
# tunnel curtains
____ (0-2)
____ (0-2)
____ (0-2)
# light programs
____ (0-8)
____ (0-8)
____ (0-8)
# vent door / inlet
____ (0-2)
____ (0-2)
____ (0-2)
Use 0-10V output?
Vent door / inlet 1 Mode
(Common to
all pro grams)
Vent door / inlet 2 Mode
(Common to
all pro grams)
Close vents in natural?
Tunnel control
(Common to
all pro grams)
# of Static P. Set points
____ (1-3)
____ (1-3)
____ (1-3)
0-10V Type
(Common to
all pro grams)
0-10V Mode
(Common to
all pro grams)
0-10V follows set point ?
(Common to
all pro grams)
Curtain 1 compensation ?
Curtain 1 Whisker switch ?
(Common to
all pro grams)
Curtain 2 compensation ?
(Common to
all pro grams)
Curtain 2 Whisker switch ?
Ramping in stage 1 ?
Use purge ?
Use misting ?
Mist follows set point ?
(Common to
all pro grams)
Use cool cell ?
Use backup relay ?
Number of outputs ?
(Common to
all pro grams)
Use age ?
(Common to
all pro grams)
Use Temp. curve ?
(Common to
all pro grams)
Number of programs
____ (1 - 3)
(Common to
all pro grams)
Switch program by age?
(Common to
all pro grams)
Switch program by Out.T° ?
(Common to
all pro grams)
Use password ?
(Common to
all pro grams)
Use passsword level:
(Common to
all pro grams)
Clear alarms ?
(Common to
all pro grams)
Digit display
(Common to
all pro grams)
ventilation
inlet
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
0-10V
10-0V
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
16
32
Yes
No
Yes
No
Yes
No
User 1
T°
SP
T°/SP
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Temperature
Static pressure
Time
Time
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
User 2
Installer
Yes
No
Static pressure
Static pressure
15.3 Installation Setup Worksheet