20
EXPERT LA rev.00
EXPERT LA
0-10V output
Select “Yes” to enable the 0-10V output.
This output can either be used to control an
air inlet or a variable fan stage.
Vent door/inlet 1-2 mode
Vent doors (inlets) can operate in two dif-
ferent ways:
Accessible if a vent door (inlet) output is enabled
above. [This parameter is common to all programs].
1. Time
The vent door (inlet) opens or closes in
timer mode, as a function of tempera-
ture.
2. Static pressure (S.P.)
The vent door (inlet) opens or closes as a
function of static pressure.
Close vents in natural
Select “Yes” for vent doors (inlets) to close
when the controller enters in natural venti-
lation.
Accessible if natural ventilation curtains and vent
doors/inlets are enabled.
Tunnel control
Does the tunnel door opens and closes ac-
cording to the static pressure level (S.P.) or
according to the room temperature.
Accessible if the tunnel curtain is activated above.
The static pressure option is only available if the
static pressure sensor is activated in section 4.7.1.
Number of static pressure set points
The controller can use up to 3 groups of
static pressure set points and each group
starts at a user-defined fan stage.
Accessible if at least one air inlet output (inlet,
vent door or tunnel curtain) operates according to
the static pressure level.
0-10V Type
Select the type of signal used by the
0-10V output (0-10V or 10-0V).
Accessible the 0-10V output is enabled above.
[This parameter is common to all programs].
0-10V mode
Select the function of the 0-10V output:
Accessible if the 0-10V output is enabled above.
[This parameter is common to all programs].
- 0-10V ventilation output
When it is used for ventilation, the
0-10V output runs similarly as a vari-
able-speed fan stage and uses indepen-
dent temperature settings.
- 0-10V inlet
When it is used as an air inlet, the
0-10V output opens and closes an ac-
tuator as a function of the ventilation
level.
0-10V output follows set point
Operating temperatures of the 0-10V out-
put can either be related to the set point –
which means the controller automatically
adjusts them when the set point changes –
or they can be set as absolute values.
Select “Yes” if they follow the set point or
select “No” if they set as absolute values.
Accessible if the 0-10V output is enabled above.
[This parameter is common to all programs].
Curtain compensation
Select "Yes" to enable a compensation on the
opening of natural ventilation curtains as a
function of the outside temperature.
Accessible if natural ventilation curtains are en-
abled above and if an outside temperature sensor
is enabled in section 4.7.1.
Main menu
Setup
User
Install.
Installation
Use to navigate
Use 0-10V Output
Yes
Vent Door/Inlet 1 Mode
Time
Vent Door/Inlet 2 Mode
S.P.
Close Vents in Natural
No
Tunnel Control
SP
#Static.P Set Points
3
0-10V Type
0-10V
0-10V Mode
Ventil.
0-10V Follow SetP
Yes
Use Curtain 1 Compens?
Yes
Use Curtain 1 Whisker?
Yes
Use Curtain 2 Compens?
Yes
Use Curtain 2 Whisker?
Yes
73
EXPERT LA rev.00
EXPERT LA
12.3 History Menus
History menus give a daily record of probe read-
ings and of the animal count. These pieces of infor-
mation are logged into history menus at midnight.
Refer to section 13.2 to consult run time histories
(for heaters, water consumption and feeders).
Select:
Main menu
History
Select the desired type of history:
•
Ambient temperature
This menu contains the daily minimum and
maximum readings of the room temperature
of the past 60 days.
•
Probe temperature
This menu contains the daily minimum and
maximum temperature readings of each tem-
perature probe for the past 10 days.
•
Outside temperature
This menu contains the daily minimum and
maximum readings of outside temperature
probes for the past 75 days.
Accessible if an outside temperature sensor is en-
abled (section 4.7.1).
•
Inside relative humidity (RH)
This menu contains the daily minimum and
maximum inside humidity readings of the
past 75 days.
Accessible if the inside humidity sensors is enabled
(sec. 4.7.1).
•
Outside relative humidity (RH)
This menu contains the daily minimum and
maximum outside humidity readings of the
past 75 days.
Accessible if the outside humidity sensors is en-
abled (sec. 4.7.1).
•
Static Pressure
This menu contains the daily minimum and
maximum static pressure readings of the
past 75 days.
Accessible if a static pressure sensor is enabled
(sec. 4.7.1).
•
Mortality / Culled / Marketed
These menus contains the daily count of
mortalities, culled, and of marketed animals
of the past 75 days.
Accessible if age-based functions are enabled (sec-
tion 4.5).
•
Water
This menu shows the daily water consump-
tion and the consumption of the past 75
days.
Main menu
History
Ambient T°
Probe T°
Outside T°
Inside RH
Outside RH
Static P.
Mortality
Culled
Marketed
History Menu