Printed Documentation
82
AS4020 Shelf Installation upgrade into AS4000 Rack
This topic covers the installation of AS4020 shelves as an upgrade into an existing AS4000
rack.
The AS4020 fits immediately below the combiner shelf in the central terminal rack. If more
than one AS4020 is to be installed existing modem shelves will need to be removed. The
AS4020 installation wiring diagrams in this manual should be used in conjunction with this
topic.
Parts required.
1
shelf
2
shelves
(1 x
AS4000
exists)
2 shelves
(2 x
AS4000
exists)
3
shelves
4
shelves
AS4020 shelf.
1
2
2
3
4
Cable tray and cover + 2 x cage
nuts, screws and washers.
1
2
2
3
4
Baseband connecting lead (part
no 454-0010-135).
1
2
2
3
4
Power connecting lead (part no
454-0010-136).
1
2
2
3
4
Alarm connecting lead (454-0010-
134).
1
2
2
3
4
Alarm Breakout connector (454-
0010-137).
1
1
2
2
2
Ethernet connecting lead (as
required).
Installing an AS4020 shelf into an existing CT rack.
1. If possible power down the rack. Note: It is possible to connect the AS4020 shelf
without removing the rack from service. However if the AS4020 is connecting via
an existing PA the service using the other RF channel in the PA must be taken
out of service to set TX sensitivity.
2. Remove the cover from the combiner switch panel and plate below the right
hand PA.
3. Remove the side panels from the rack.
4. Remove existing 100mm cover from below the combiner shelf.
5. Run the power connecting lead (part no 454-0010-136) from the combiner shelf
backplane (socket J13) to the left hand side of the shelf position for the AS4020.
In a 4 Shelf loom this socket may have a plug inserted but it should not be
connected to any equipment and can be removed.
In order to connect the lead it is best to remove the switch from the combiner
shelf. If the rack is still in service the power plug can be removed and the new one
Summary of Contents for AS4000
Page 2: ......
Page 6: ...Printed Documentation 2 ...
Page 14: ...Printed Documentation 10 ...
Page 16: ...Printed Documentation 12 ...
Page 27: ...Installation 23 Typical 75ohm DDF Layout ...
Page 28: ...Printed Documentation 24 ...
Page 41: ...Installation 37 ...
Page 42: ...Printed Documentation 38 BNC Terminations to Coax ...
Page 43: ...Installation 39 Type 43 Terminations to Coax ...
Page 44: ...Printed Documentation 40 ...
Page 52: ...Printed Documentation 48 ...
Page 68: ...Printed Documentation 64 ...
Page 71: ...Installation 67 ...
Page 72: ...Printed Documentation 68 CT Rack Labelling Central Terminal Rack ...
Page 73: ...Installation 69 BNC Terminations to Coax ...
Page 74: ...Printed Documentation 70 Type 43 Terminations to Coax ...
Page 75: ...Installation 71 ...
Page 78: ...Printed Documentation 74 Card Insertion DA Rack Card Insertion Expansion Rack ...
Page 110: ...Printed Documentation 106 ...
Page 112: ...Printed Documentation 108 Combiner Shelf PSU ...
Page 133: ...Setup and Test 129 ...
Page 163: ...Setup and Test 159 ...
Page 166: ......
Page 170: ...Printed Documentation 166 ...
Page 176: ...Printed Documentation 172 ...
Page 192: ......