Setup and Test
115
Measuring Central Terminal TX Power
The recommended single user TX output power is +18dBm for 3.4-3.6GHz, +20dBm for 1.8-
1.9GHz, and +21dBm for all other bands. This procedure is used to measure the TX output
power when set up for 3 Users.
Note: If proceeding to commissioning the DACU should be powered up and allowed to warm
up for 30 mins prior to setting the RX sensitivity..
This procedure is for setting up AS4000 shelves only.
Tools and equipment needed.
Item
Description
Recommended Model
Quantity
1
50 ohm Termination 10W ArraN9510
1
2
RF Power Meter
Anritsu Sitemaster S400A or
Marconi 6970
1
3
Power Sensor
Anritsu 560-7N50B or Marconi
6932
1
4
Attenuator for use with
Anritsu
HP 8491 (N Type)
1
Test TX Output Power (Test 5)
Note: If adding a shelf to a rack that is already in service it is necessary to
remove any shelf sharing the power amplifier from service in order to make
power measurements. This is best done when traffic loading is at its lowest
In order to commission the output power of the rack, a Power Meter must be
connected via a power sensor to the N-Type connector on the DIP/LNA at the top of
the rack. Protect the meter by connecting a 30dB attenuator (HP 8491) to the output
of the DIP/LNA as the output power can exceed 33dBm.
1. Note: The output from shelves 1 and 2 is measured on DIP/LNA1. The outputs from
shelves 3 and 4 are measured on the DIP/LNA2. The port not under test should be
terminated with a 10W termination.
Summary of Contents for AS4000
Page 2: ......
Page 6: ...Printed Documentation 2 ...
Page 14: ...Printed Documentation 10 ...
Page 16: ...Printed Documentation 12 ...
Page 27: ...Installation 23 Typical 75ohm DDF Layout ...
Page 28: ...Printed Documentation 24 ...
Page 41: ...Installation 37 ...
Page 42: ...Printed Documentation 38 BNC Terminations to Coax ...
Page 43: ...Installation 39 Type 43 Terminations to Coax ...
Page 44: ...Printed Documentation 40 ...
Page 52: ...Printed Documentation 48 ...
Page 68: ...Printed Documentation 64 ...
Page 71: ...Installation 67 ...
Page 72: ...Printed Documentation 68 CT Rack Labelling Central Terminal Rack ...
Page 73: ...Installation 69 BNC Terminations to Coax ...
Page 74: ...Printed Documentation 70 Type 43 Terminations to Coax ...
Page 75: ...Installation 71 ...
Page 78: ...Printed Documentation 74 Card Insertion DA Rack Card Insertion Expansion Rack ...
Page 110: ...Printed Documentation 106 ...
Page 112: ...Printed Documentation 108 Combiner Shelf PSU ...
Page 133: ...Setup and Test 129 ...
Page 163: ...Setup and Test 159 ...
Page 166: ......
Page 170: ...Printed Documentation 166 ...
Page 176: ...Printed Documentation 172 ...
Page 192: ......