Printed Documentation
136
Go to Top Menu >Setup Menu >RF Menu>TX Power
TX power
To set the CT to transmit at QPSK or 16QAM adjust the TX Power until the output of the
transmitter by increasing or decreasing the value until the level tabulated below is
reached. If the CT is required to operate with a downlink of 64QAM then the output
should be backed off by 3dB.
Note:
This will affect the system coverage and should be
taken into account at the radio planning stage.
Band
Power Meter
Reading QPSK and
16QAM
Power Meter Reading for
64QAM
P
See Below
N/A
X
21.4dBm
18.4dBm
All
other
24.4dBm
21.4dBm
P Band
To comply with FCC requirements for Spurious Emissions at Block Edges, the transmit
power of the CT should be reduced for channels 180, 181, 214 and 215 as detailed below.
Channel
Downlink
(MHz)
Uplink
(MHz)
Power
Commissioning
mode 1
180
1932.00
1852.00
18.9 dBm
181
1933.00
1853.00
22.4 dBm
182 to
213
-
-
23.4dBm
214
1987.00
1907.00
22.4 dBm
215
1988.00
1908.00
19.4 dBm
Record the value and output level.
Set commissioning mode to Off, then set to commissioning mode 3. Check that the power
meter reading increases by 8.7dB (+/- 1dB). If the reading is lower RF compression may
be occurring.
Note if it is required to measure the output power with all the RWs enabled set the CT
commissioning mode to
off
and then set the commissioning mode to 2. This sets all 13
RWs active. To return to commissioning mode 1 set the CT commissioning mode to off
and then set the commissioning mode to 1. (Note the setting to off is important and it is
not possible to go directly between 1 and 2.)
Summary of Contents for AS4000
Page 2: ......
Page 6: ...Printed Documentation 2 ...
Page 14: ...Printed Documentation 10 ...
Page 16: ...Printed Documentation 12 ...
Page 27: ...Installation 23 Typical 75ohm DDF Layout ...
Page 28: ...Printed Documentation 24 ...
Page 41: ...Installation 37 ...
Page 42: ...Printed Documentation 38 BNC Terminations to Coax ...
Page 43: ...Installation 39 Type 43 Terminations to Coax ...
Page 44: ...Printed Documentation 40 ...
Page 52: ...Printed Documentation 48 ...
Page 68: ...Printed Documentation 64 ...
Page 71: ...Installation 67 ...
Page 72: ...Printed Documentation 68 CT Rack Labelling Central Terminal Rack ...
Page 73: ...Installation 69 BNC Terminations to Coax ...
Page 74: ...Printed Documentation 70 Type 43 Terminations to Coax ...
Page 75: ...Installation 71 ...
Page 78: ...Printed Documentation 74 Card Insertion DA Rack Card Insertion Expansion Rack ...
Page 110: ...Printed Documentation 106 ...
Page 112: ...Printed Documentation 108 Combiner Shelf PSU ...
Page 133: ...Setup and Test 129 ...
Page 163: ...Setup and Test 159 ...
Page 166: ......
Page 170: ...Printed Documentation 166 ...
Page 176: ...Printed Documentation 172 ...
Page 192: ......