Setup and Test
133
Set TX Power
The recommended single user TX output power (QPSK/16QAM) is +18dBm for 3.4-3.6GHz,
+20dBm for 1.8-1.9GHz, and +21dBm for all other bands. This procedure is used to measure
the TX output power when set up in commissioning mode 1.
System Soak
It is necessary that the system is powered up for at least two hours to allow for
temperature stabilisation before proceeding with the measurement of the TX power
Tools and equipment needed.
Item
Description
Recommended Model
Quantity
1
50 ohm Termination
10W
ArraN9510
1
2
RF Power Meter
Anritsu Sitemaster S400A or
Marconi 6970
1
3
Power Sensor
Anritsu 560-7N50B or Marconi
6932
1
4
Attenuator for use with
Anritsu
HP 8491 (N Type)
1
Test TX Output Power (Test 5)
Note: If adding a shelf to a rack that is already in service it is necessary to
remove the RF card for any shelf sharing the power amplifier in order to make
power measurements. This is best done when traffic loading is at its lowest
In order to commission the output power of the rack, a Power Meter must be
connected via a power sensor to the N-Type connector on the DIP/LNA at the top of
the rack. Protect the meter by connecting a 30dB attenuator (HP 8491) to the output
of the DIP/LNA as the output power can exceed 33dBm.
Note:
The output from RF cards 1 and 2 is measured on DIP/LNA1. The output from
RF cards 3 and 4 is measured on the DIP/LNA2. If the AS4020 shelf has been added
to an existing rack then the RF card used must be inserted prior to measuring the shelf
power. The port not under test if not connected to an antenna should be terminated
with a 10W termination.
Measure the output of AS4020.
(This test is repeated for other installed AS4020
shelves)
Connect RF meter via a 30dB attenuator on the antenna port to protect the power sensor
from damage.
Configure the AS4020 using the menus on the front panel. From the Top Menu >Setup
Menu >RF Menu set the following values:
Note:
The PN code should always be set prior to entering commissioning mode.
RF Menu
TX Clipping
00101
Disable TX and RX
False
Downlink Frequency
Enter DL frequency kHz with leading 0 e.g 03522751
Summary of Contents for AS4000
Page 2: ......
Page 6: ...Printed Documentation 2 ...
Page 14: ...Printed Documentation 10 ...
Page 16: ...Printed Documentation 12 ...
Page 27: ...Installation 23 Typical 75ohm DDF Layout ...
Page 28: ...Printed Documentation 24 ...
Page 41: ...Installation 37 ...
Page 42: ...Printed Documentation 38 BNC Terminations to Coax ...
Page 43: ...Installation 39 Type 43 Terminations to Coax ...
Page 44: ...Printed Documentation 40 ...
Page 52: ...Printed Documentation 48 ...
Page 68: ...Printed Documentation 64 ...
Page 71: ...Installation 67 ...
Page 72: ...Printed Documentation 68 CT Rack Labelling Central Terminal Rack ...
Page 73: ...Installation 69 BNC Terminations to Coax ...
Page 74: ...Printed Documentation 70 Type 43 Terminations to Coax ...
Page 75: ...Installation 71 ...
Page 78: ...Printed Documentation 74 Card Insertion DA Rack Card Insertion Expansion Rack ...
Page 110: ...Printed Documentation 106 ...
Page 112: ...Printed Documentation 108 Combiner Shelf PSU ...
Page 133: ...Setup and Test 129 ...
Page 163: ...Setup and Test 159 ...
Page 166: ......
Page 170: ...Printed Documentation 166 ...
Page 176: ...Printed Documentation 172 ...
Page 192: ......