Chapter 10
Preparing to Run a Fiber Autotest 82
Length/Loss Method
lets the WireScope 350 calculate the limit for you based
on the length of the cable tested. You will be able to set values for
Connectors
,
Loss per Connector
,
Splices
, and
Loss per Splice
. The connector and splice
losses are added to the loss calculated by multiplying the length of the fiber by
the loss/Km specification of the selected cable. These specifications are shown
at the bottom of the Setup screen.
Press
OK
or
to complete the setup. You will be returned to the Fiber
Autotest Settings screen.
Length Limit
The Length Limit parameter allows you to set the maximum cable length
allowed. To change the length select
Length Limit
and press
or
Edit
.
Press the edit icon to pop up a numeric data entry keypad. Enter the length and
press
OK
or
to close the keypad.
Press
OK
or
to complete the setup and return you to the Fiber Autotest
Settings screen.