Chapter 5
Running an Autotest 58
Diagnostics
The Diagnostics section of the DualRemote 350 front panel provides more
detailed information about failing test results.
WS and DR LEDs indicate at which end of the tested cable the measurement
failed.
A column of diagnostic LEDs provide further detail about the cause(s) of a test
failure. The failure causes that can be indicated are:
·
Wiremap
·
Split pairs
·
Length / Delay / Skew (any of these conditions)
·
NEXT (pair-to-pair or power sum)
·
Attenuation
·
ELFEXT (pair-to-pair or power sum)
·
Return Loss
·
Other (any other failing measurement)
In the event that the cabling run has multiple test failure causes (i.e. NEXT and
Return Loss), you can use the
key to scroll between failure cause indications.
The current selection is indicated by a blinking LED. The pair indicators and
WS/DR indicators will blink to show which pairs and which cable end
correspond to the selected failure cause.
Power LED
The power LED indicates on / off status for the DualRemote 350. When this
LED is lit, the DualRemote 350 is powered on.
Test failed at
WireScope end of
cabling run
Test failed at
DualRemote end of
cabling run
Test failed at both
ends of cabling run
Summary of Contents for WireScope 350
Page 1: ...www wirescope com W i r e S c o p e 3 5 0 U s e r s G u i d e...
Page 13: ...Chapter 1 Introduction 12...
Page 17: ...Chapter 2 Cable Testing Overview 16...
Page 45: ...Chapter 4 Preparing to Run an Autotest 44...
Page 63: ...Chapter 6 Certify Networks 62...
Page 69: ...Chapter 7 Tools 68...
Page 99: ...Chapter 11 Running Fiber Autotest 98...
Page 103: ...Chapter 12 Fiber Certify Networks 102...
Page 111: ...Chapter 13 Fiber Tools 110...
Page 137: ...Chapter 16 Using the Talkset Option 136...
Page 149: ...Appendix C Legacy Networks 148...
Page 153: ...Appendix D Battery information 152...