Chapter 15
WireScope 350 System Settings 117
Using the Database viewer
You can view any of the data saved in the WireScope 350’s local flash memory
or an installed CompactFlash™ card by using the database viewer.
To run the database viewer, from the main menu, press
Database
. The Database
menu screen will appear.
Viewing saved tests
To view saved tests, from the Database menu screen, press
or the
Tests
Database
button.
The tests database screen will appear showing a summary listing of saved test
results. Each saved result has an associated summary result icon, which allows
you to see at a glance to see pass/fail status and test type. For example:
Denotes a Category 6 autotest which passed
Denotes a Category 5E autotest which failed
Number of tests in
database
Number of tests in
select ed sit e
Summary result icons
w ith cable labels for
saved tests
Use t he
key to
scroll t he list of
results.