Chapter 4
Preparing to Run an Autotest 31
Specifying the cable
You must specify either the part number or the performance characteristics of
the cable under test in order for the WireScope 350 to make accurate length
measurements. You can either select the cable part number from a pre-loaded
list of the most popular cable types or you can enter the cable part number and
specifications.
If you manually enter cable specifications, it is important to input accurate
values for the nominal velocity of propagation (NVP) for each cable pair.
Failure to do so will produce inaccurate cable length and distance-to-fault
measurements.
To enter cable information starting at the Autotest Settings screen, select the
cable icon and press
or
Edit
.
The Cable Setup configuration screen prompts you to specify the manufacturer
of the cable that you will be testing. If you do not know the manufacturer, select
“unspecified”. Use the
key if you need to scroll the list of manufacturers. In
the example above, “Lucent” is selected. Then, press
or
Next
.
Summary of Contents for WireScope 350
Page 1: ...www wirescope com W i r e S c o p e 3 5 0 U s e r s G u i d e...
Page 13: ...Chapter 1 Introduction 12...
Page 17: ...Chapter 2 Cable Testing Overview 16...
Page 45: ...Chapter 4 Preparing to Run an Autotest 44...
Page 63: ...Chapter 6 Certify Networks 62...
Page 69: ...Chapter 7 Tools 68...
Page 99: ...Chapter 11 Running Fiber Autotest 98...
Page 103: ...Chapter 12 Fiber Certify Networks 102...
Page 111: ...Chapter 13 Fiber Tools 110...
Page 137: ...Chapter 16 Using the Talkset Option 136...
Page 149: ...Appendix C Legacy Networks 148...
Page 153: ...Appendix D Battery information 152...