3.1.6.2. AUTORECALL MODE submenu.
AUTORECALL MODE function defines the way a communication channel will act when the unit
starts up. There are 4 different modes and can be independently configured for both
communication channels:
-
DISABLED: the channel establishes no automatic communication at all (by default).
-
ALWAYS CALL TO: when the unit starts up, the channel launches a call to a
previously specified number/URI. The number/URI that will be used is the one that
appears when you press the CALL button of the selected channel. Therefore, in
order to configure this option, press CALL just like if you were about to make a call
to the desired equipment, configure the desired number/URI, press ESC and enter
the channel menu in order to activate this mode.
-
REDIAL INTERRUPTED CALL: when the unit starts up, the channel launches an
automatic call as long as the communication with that number were established
when the unit was turned off (due to a power supply failure, for instance).
-
REDIAL INTERRUPTED OUTGOING CALL: when the unit starts up, the channel
launches an automatic call as long as the communication with that number were
established when the unit was turned off (due to a power supply failure, for
instance) and that call were also made by the local unit.
NOTE: When the channel is working in IP - RTP mode, the call will be restablished only when
the remote unit is still connected, but it could be disconnected when RTP INACTIVIY MODE is
activated and enough time has passed by. In this case, we recommend you to activate
additionally the BACK UP function in order to guarantee a failureproof link.
3.1.7. MAINTENANCE menu.
Internal maintenance menu for the codec. You can access the MAINTENANCE menu from the
SYSTEM MENU, in the seventh option, by pressing the rotary encoder. It is internally divided
into a series of submenus:
-
FW VERSION: enables you to consult the firmware versions of the various PHOENIX
STRATOS basic modules (DSP, FPGA and CPU), as well as the ISDN module. More
information in section 1.4.
-
REMOTE CONTROL SETTINGS: allows you to configure the unit to accept incoming
remote control connections. Make sure that there is connection with the PC where
“AEQ ControlPHOENIX” application is installed, the display headline shows an “(R)” to
indicate it (independently of the menu we have selected).