IQ 710 System Manual
© 2002 ADTRAN, Inc.
61202800L1-1B
IQ 710
Section 6, Configuration Guides
Page 184
3.
Press the right arrow once and then down arrow until
PVC O
PTIONS
is selected. Press
<Enter>
and
the screen shown in Figure 19 is shown.
Figure 19. PVC Options Menu
Huntsville IQ 710 (DLCI 16)
1.
Use the right arrow to select
DLCI
; then press
<Enter>
. Type in 16 and press
<Enter>
.
2.
Use the right arrow to select
DBU DLCI
; then press
<Enter>
. Type in 17 and press
<Enter>
.
Notice that the TELCO-assigned DLCI of 16 for Huntsville's Frame Relay link to Atlanta is pro-
grammed in the
DLCI
field. The TELCO-assigned DLCI of 17 for Atlanta's Frame Relay link to
Huntsville is programmed in the
DBU DLCI
field. These two entries are critical for proper dial
backup operation.
3.
Use the right arrow to select
DBU P
HONE
N
UMBER
; then press
<Enter>
. Type in 17705552000 and
press
<Enter>
. The phone number that the Huntsville IQ 710 will dial to reach the Atlanta IQ 710 to
establish a dial backup connection has now been programmed.
4.
Use the right arrow to select
C
ALL
O
RDER
N
UMBER
.
DBU C
ALL
O
RDER
allows each DLCI listed in
the table to be prioritized in the event that multiple PVCs are lost at once. Dial backup will first be
attempted on the PVC with the lowest Call Order that meets the DBU Criteria settings. Set this Call
Order to 2.
5.
Use the right arrow to select
DBU O
N
I
NACTIVE
; then press
<Enter>
.
6.
Down arrow to select
G
ROUP
; then press
<Enter>
.