61202800L1-1B
IQ 710
Section 6, Configuration Guides
Page 187
© 2002 ADTRAN, Inc.
IQ 710 System Manual
At this point all PVC Options have been configured for basic Frame Relay dial backup to Atlanta and Bir-
mingham. The PVC entries on the Huntsville IQ 710 should look like the screen shown in Figure 22. The
remaining options may be left at their default values. The
CIR
,
S
EQUENCE
N
UMBER
C
HECKING
,
D
ELAY
M
EA
-
SUREMENT
, and
S
TATS
options are features not related to dial backup. For an explanation of these features,
please refer to the IQ 710 User Manual.
Figure 22. Huntsville IQ 710 (DLCI 17) Screen
Atlanta IQ 710 (DLCI 17)
1.
Use the right arrow to select
DLCI
; then press
<Enter>
. Type in 17 and press
<Enter>
.
2.
Use the right arrow to select
DBU DLCI
; then press
<Enter>
. Type in 16 and press
<Enter>
.
Notice that the TELCO-assigned DLCI of 16 for Atlanta's Frame Relay link to Huntsville is pro-
grammed in the DLCI field. The TELCO-assigned DLCI of 16 for Huntsville's Frame Relay link to
Atlanta is programmed in the
DBU DLCI
field. These two entries are critical for proper dial backup
operation.
3.
Use the right arrow to select
DBU P
HONE
N
UMBER
; then press
<Enter>
. Type in 12565551000 and
press
<Enter>
. The phone number that the Atlanta IQ 710 will dial to reach the Huntsville IQ 710 to
establish a dial backup connection has now been programmed.