61202800L1-1B
IQ 710
Section 6, Configuration Guides
Page 267
© 2002 ADTRAN, Inc.
IQ 710 System Manual
Huntsville IQ 710 (DLCI 800)
1.
Using the left arrow, place the cursor over the number 3 (indicating entry 3) to the left of the
DLCI
field; then press
<I>
for insert. This should add an entry as shown in Figure 26.
Figure 26. New Entry Screen
2.
Now add the DLCI to the Mobile site. Use the right arrow to select
DLCI
; then press
<Enter>
. Type
in 800 and press
<Enter>
.
3.
Use the right arrow to select
DBU DLCI
; then press
<Enter>
. Type in 700 and press
<Enter>
.
Notice that the TELCO-assigned DLCI of 800 for Huntsville's Frame Relay link to Mobile is pro-
grammed in the DLCI field. The TELCO-assigned DLCI of 700 for Mobile's Frame Relay link to
Huntsville is programmed in the
DBU DLCI
field. These two entries are critical for proper dial
backup operation.
4.
Use the right arrow to select
DBU P
HONE
N
UMBER
; then press
<Enter>
. Type in 13345555000 and
press
<Enter>
. The phone number that the Huntsville IQ 710 will dial to reach the Mobile
IQ 710 to establish a dial backup connection has now been programmed.
5.
Use the right arrow to select
C
ALL
O
RDER
N
UMBER
.
DBU C
ALL
O
RDER
allows each DLCI listed in
the table to be prioritized in the event that multiple PVCs are lost at once. Dial backup will first be
attempted on the PVC with the lowest Call Order that meets the DBU Criteria settings. Set this
Call Order to 4.
6.
Use the right arrow to select
DBU O
N
I
NACTIVE
; then press
<Enter>
. Down arrow to select
E
NABLED
; then press
<Enter>
.