4.
Use the right arrow key to select
DLCI
. Press
<Enter>.
Type in 20 and press
<Enter>.
This is the
DLCI that Montgomery uses for communication with Huntsville.
5.
Select
DBU DLCI
. Press
<Enter>.
Type in 17 and press
<Enter>.
This is the DLCI that the Hunts-
ville IQ 710 uses to communicate with Montgomery.
6.
Select
DBU P
HONE
N
UMBER
. Press
<Enter>.
Type in 12565551000 and press
<Enter>.
7.
Select
DBU
ON
I
NACTIVE
. Press
<Enter>.
Select
E
NABLED
. Press
<Enter>.
Since there is only one PVC for Montgomery, there is no need to enter another entry into the PVC
table. At this point the Montgomery IQ 710 is configured for basic dial backup to Huntsville. The
C
ONFIGURE
PVC O
PTIONS
screen is shown in Figure 46. The remaining options may be left at their
default values. These features are not related to dial backup. For an explanation of these features,
please refer to the User Manual.
Figure 46. Configure PVC Options Screen