61202800L1-1B
IQ 710
Section 6, Configuration Guides
Page 189
© 2002 ADTRAN, Inc.
IQ 710 System Manual
4.
Use the right arrow to select
DBU PHONE NUMBER
; then press
<Enter>
. Type in 12565551000
and press
<Enter>
. The phone number that the Atlanta IQ 710 will dial to reach the Huntsville
IQ 710 to establish a dial backup connection has now been programmed.
5.
Use the right arrow to select
C
ALL
O
RDER
N
UMBER
.
DBU C
ALL
O
RDER
allows each DLCI listed in
the table to be prioritized in the event that multiple PVCs are lost at once. Dial backup will first be
attempted on the PVC with the lowest Call Order that meets the DBU Criteria settings. Leave this
parameter at the default value of none.
The
DBU O
N
I
NACTIVE
parameter is disabled by default. For this example, leave it disabled in order
to assure the
G
ROUP
parameter on the host unit will initiate dial backup.
At this point all PVC Options have been configured for basic Frame Relay dial backup to Huntsville. The
PVC entries on the Atlanta IQ 710 should look like the screen shown in Figure 24. The remaining options
may be left at their default values. The
CIR
,
S
EQUENCE
N
UMBER
C
HECKING
,
D
ELAY
M
EASUREMENT
, and
S
TATS
options are features not related to dial backup. For an explanation of these features, please refer to
the IQ 710 User Manual.
Figure 24. Atlanta IQ 710 PVC Options Screen