IQ 710 System Manual
© 2002 ADTRAN, Inc.
61202800L1-1B
IQ 710
Section 6, Configuration Guides
Page 264
3.
Press the right arrow once and then down arrow until
PVC O
PTIONS
is selected. Press
<Enter>
and the screen shown in Figure 23 is shown.
Figure 23. PVC Options Menu
Huntsville IQ 710 (DLCI 200)
1.
Use the right arrow to select
DLCI
; then press
<Enter>
. Type in 200 and press
<Enter>
.
2.
Use the right arrow to select
DBU DLCI
; then press
<Enter>
. Type in 100 and press
<Enter>
.
Notice that the TELCO-assigned DLCI of 200 for Huntsville's Frame Relay link to Atlanta is pro-
grammed in the
DLCI
field. The TELCO-assigned DLCI of 100 for Atlanta's Frame Relay link to
Huntsville is programmed in the
DBU DLCI
field. These two entries are critical for proper dial
backup operation.
3.
Use the right arrow to select
DBU P
HONE
N
UMBER
; then press
<Enter>
. Type in 17705552000 and
press
<Enter>
. The phone number that the Huntsville IQ 710 will dial to reach the Atlanta IQ 710 to
establish a dial backup connection has now been programmed.
4.
Use the right arrow to select
C
ALL
O
RDER
N
UMBER
.
DBU C
ALL
O
RDER
allows each DLCI listed in
the table to be prioritized in the event that multiple PVCs are lost at once. Dial backup will first be
attempted on the PVC with the lowest Call Order that meets the DBU Criteria settings. Set this
Call Order to 1.
5.
Use the right arrow to select
DBU O
N
I
NACTIVE
; then press
<Enter>
. Select
E
NABLED
and press
<Enter>.