IQ 710 System Manual
© 2002 ADTRAN, Inc.
61202800L1-1B
IQ 710
Section 6, Configuration Guides
Page 186
Huntsville IQ 710 (DCLI 20)
1.
Using the left arrow, place the cursor over the number 2 (indicating entry 2) to the left of the
DLCI
field; then press
<I>
for insert. This should add an entry as shown in Figure 21.
Figure 21. New Entry Screen
2.
Now add the DLCI to the Birmingham site. Use the right arrow to select
DLCI
; then press
<Enter>
.
Type in 20 and press
<Enter>
.
3.
Use the right arrow to select
DBU DLCI
; then press
<Enter>
. Type in 21 and press
<Enter>
.
Notice that the TELCO-assigned DLCI of 20 for Huntsville's Frame Relay link to Birmingham is
programmed in the DLCI field. The TELCO-assigned DLCI of 21 for Birmingham's Frame Relay
link to Huntsville is programmed in the
DBU DLCI
field. These two entries are critical for proper
dial backup operation.
4.
Use the right arrow to select
DBU P
HONE
N
UMBER
; then press
<Enter>
. Type in 12055553000 and
press
<Enter>
. The phone number that the Huntsville IQ 710 will dial to reach the Birmingham
IQ 710 to establish a dial backup connection has now been programmed.
5.
Use the right arrow to select
C
ALL
O
RDER
N
UMBER
.
DBU C
ALL
O
RDER
allows each DLCI listed in
the table to be prioritized in the event that multiple PVCs are lost at once. Dial backup will first be
attempted on the PVC with the lowest Call Order that meets the DBU Criteria settings. Set this Call
Order to 1.
6.
Use the right arrow to select
DBU O
N
I
NACTIVE
; then press
<Enter>
. Down arrow to select
G
ROUP
;
then press
<Enter>
.