61202800L1-1B
IQ 710
Section 6, Configuration Guides
Page 165
© 2002 ADTRAN, Inc.
IQ 710 System Manual
Figure 19. New Entry Screen
2.
Use the right arrow to select
DLCI
; then press
<Enter>
. Type in 17 and press
<Enter>
.
3.
Use the right arrow to select
DBU DLCI
; then press
<Enter>
. Type in 20 and press
<Enter>
.
4.
Use the right arrow to select
DBU P
HONE
N
UMBER
; then press
<Enter>
. Type in 12055553000 and
press
<Enter>
. The phone number that the Huntsville IQ 710 will dial to reach the Birmingham
IQ 710 to establish a dial backup connection has now been programmed.
5.
Use the right arrow to select
DBU O
N
I
NACTIVE
; then press
<Enter>
. Down arrow to select
E
NABLED
;
then press
<Enter>
. This allows the Huntsville IQ 710 to dial out to the IQ 710 in Birmingham in the
event that DLCI 17 is advertised as Inactive by the Frame Relay switch.
All necessary parameters for the Huntsville IQ 710 have now been configured for dial backup
between Huntsville and Birmingham. The
C
ONFIGURE
PVC O
PTIONS
screen for Huntsville is shown
in Figure 20.