IQ 710 System Manual
© 2002 ADTRAN, Inc.
61202800L1-1B
IQ 710
Section 5, Detail Level Procedures
Page 130
Dial Options during DIal Backup (for V.34, BRI ISDN, and DCE DBU modules):
1.
The
H
ANG
UP
option will terminate the current dial backup session and attempt to reestablish com-
munication on the dedicated line.
2.
The
T
URN
O
FF
B
EEP
option will discontinue the audible beep for the duration of the current DBU
session.
Dial Options during DIal Backup (for PRI DBU module):
1.
The
E
NTER
D
IAL
#
option will force the unit to attempt dial backup to the site corresponding to the
phone number entered.
2.
The
H
ANG
U
P
P
HONE
#
option will disconnect the DBU session to the site corresponding to the
phone number entered.
3.
The
H
ANG
U
P
S
ITE
#
option is only available on the terminal interface. This option will disconnect
the dial backup session to a specific site. The site number may be obtained from the call manager
menu.
4.
The
H
ANG
U
P
A
LL
C
ALLS
option will disconnect all dial backup sessions currently active.
5.
The
T
URN
O
FF
B
EEP
option will discontinue the audible beep for the duration of the current DBU
session.
Front Panel Directions
Dial Options When Dial Backup is Idle (all DBU modules):
1.
Press 4 for
D
IAL
and press
<Enter>
.
2.
The cursor will then be flashing on 1 for
D
IAL
B
ACKUP
. Press
<Enter>
. If
S
TAY
ON
L
EASED
is
selected, the IQ 710 will remain on the leased line and will not enter dial backup mode. The
S
TAY
ON
L
EASED
option is not available with a PRI DBU card installed.
3.
The cursor will then be flashing on 1 for
E
NTER
D
IAL
#
. Press
<Enter>
.
4.
Enter the phone number and press
<Enter>
.
5.
Press
2
for
D
IAL
and press
<Enter>
. The unit will then initiate a manual dial backup session.
Dial Options during DIal Backup (for V.34, BRI ISDN, and DCE DBU modules):
1.
Press 4 for
D
IAL
and press
<Enter>
.
2.
Press 1 for
H
ANG
UP
and press
<Enter>
to terminate the current dial backup session and attempt
to reestablish communication on the dedicated line.
3.
Press 2 for
T
URN
O
FF
B
EEP
and press
<Enter>
to discontinue the audible beep for the duration of
the current DBU session.