61202800L1-1B
IQ 710
Section 5, Detail Level Procedures
Page 91
© 2002 ADTRAN, Inc.
IQ 710 System Manual
SETTING IP PARAMETERS FOR THE IQ 710
Introduction
If the IQ 710 is connected to an IP network for Telnet, TFTP, or SNMP management, there are several IP
parameters that must be set in order for the unit to communicate with the network. These parameters are
described in this DLP along with the procedures for setting them.
Prerequisite Procedures
This procedure assumes that the IQ 710 unit is connected to an IP network and is powered up.
Tools and Materials Required
•
Male-to-female DB-9 cable (customer-provided) to connect to either a VT-100 terminal or a PC con-
figured as a VT-100 terminal
•
VT-100 terminal or PC configured as a VT-100 terminal
•
DB-9 to DB-25 adapter if the PC’s com port is DB-25 (customer-provided)
Please see your Network Administrator for the proper assignment of the following
parameters: IP address, Subnet Mask, and Default Gateway.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling
modules, wear an antistatic discharge wrist strap to prevent damage to electronic
components. Place modules in antistatic packing material when transporting or storing.
When working on modules, always place them on an approved antistatic mat that is
electrically grounded.