5
Ext Bits Mode
This option is used to set the type of signal connected to
External Bit B and C on the Total Access 3000 shelf. The
options are as follows:
• T1
• E1
• 2Mhz Square Wave
6
Stratum 3E Holdover
This option is used to enable or disable Stratum 3E
Holdover capability of the system.
To enable the Stratum 3E Holdover, the Stratum 3E Clock
module (P/N 1181930L1) must be installed in Slot 1 of the
Primary Total Access 3000 shelf.
Line Code
This field displays the Line Code type. The DS3 interface
uses B3ZS as defined in ANSI T1.102-1993. Though Line
Code is displayed on the Provisioning menu, it is set by the
manufacturer and cannot be changed.
8
Restore Factory Defaults
This option is used to restore the DS3 and Timing
Provisioning options to the following factory default values:
• Framing: C-BIT, MAPPED
• Line Length (meters): 0
• Primary Timing: LOOP
• Secondary Timing: NONE
• Line Code: B3ZS
Table 22. DS3 and Timing Provisioning Menu Options (Continued)