Total Access 3000 DSLAM DS3 Primary Switch Module Installation and Maintenance Practice

44

 

61181041L3-5A

Shelf # Slot # Port # Buffer, CAC, & Policing Options Menu
The Shelf # Slot # Port # Buffer, CAC, & Policing Options menu (see 

Figure 21

) is used to 

manage Port settings for the selected port. This menu is accessed by pressing the 

P

 hot key on 

any of the Buffer, CAC, & Policing Options menus.

Figure 21.  Shelf # Slot # Port # Buffer, CAC, & Policing Options Menu

The Shelf # Slot # Port # Buffer, CAC, & Policing Options menu options are shown in 

Table 19

.

Table 19.  Shelf # Slot # Port # 

Buffer, CAC, & Policing Options Menu Options

Option 

Description

Function

2

Override

This option is used to control policing override. 

4

Override

This option is used to control Cell Rate CAC override.

6

Override

This option is used to control Cell Buffer CAC override.

8

Override

This option is used to control AIS/RDI Generation override.

10

Override

This option is used to control Default Input Cell Delay 
Variation Tolerance (CDVT) override.

12

Override

This option is used to control CBR Overbooking % setting 
override.

14

Override

This option is used to control rtVBR Overbooking % setting 
override.

16

Override

This option is used to control nrtVBR Overbooking % 
setting override.

Shelf: 1 Slot: B               Total Access System                    MM/DD/YY HH:MM
                                                                ONLINE

            Shelf 1 Slot 1 Port 1 Buffer, CAC, & Policing Options

                        Policing : ENABLED          2.  Override : FALSE
                   Cell Rate CAC : ENABLED          4.  Override : FALSE
                 Cell Buffer CAC : DISABLED         6.  Override : FALSE
              AIS/RDI Generation : ENABLED          8.  Override : FALSE
              Default Input CDVT : 0                10. Override : FALSE
               CBR Overbooking % : 100              12. Override : FALSE
             rtVBR Overbooking % : 100              14. Override : FALSE
            nrtVBR Overbooking % : 100              16. Override : FALSE

        Maximum Buffer Threshold : 131071           18. Override : FALSE
            CBR Class Scheduling : Modified Strict  20. Override : FALSE
          rtVBR Class Scheduling : Modified Strict  22. Override : FALSE
         nrtVBR Class Scheduling : Modified Strict  24. Override : FALSE
            UBR Class Scheduling : Strict Priority  26. Override : FALSE

 S-System, W-WAN, L-Loop, P-Port, Selection:

                            '?' - System Help Screen

Summary of Contents for DS3-PSM

Page 1: ...Total Access 3000 DSLAM DS3 Primary Switch Module Installation and Maintenance Practice Document Number 61181041L3 5A CLEI M3C3LT0A November 2005 DS3 PSM 1181041L3...

Page 2: ...e Holder of the Manual The contents of this publication are current as of the date of publication ADTRAN reserves the right to change the contents without prior notice In no event will ADTRAN be liabl...

Page 3: ...nt indicates references to other documentation and is also used for emphasis This font indicates on screen messages and prompts This font indicates text to be typed exactly as shown This font indicate...

Page 4: ...de overviews on product features and functions while covering applications of ADTRAN product lines ADTRAN provides a variety of training options including customized training and courses taught at our...

Page 5: ...larm Indication RAI 8 Compliance 8 Front Panel LEDs 9 Pushbuttons 10 Installation 10 Shipping Contents 10 Instructions for Installing the Module 11 Connect and Logon 11 Provisioning 12 Autoprovisionin...

Page 6: ...creen MGMT Port Menu 62 Traffic Descriptor Screen 65 Create Traffic Descriptor Screen 67 VC VP Provisioning Screen 69 Detailed PVC Information Screen 71 VC VP Provisioning Create PVC PVP Menu 73 Searc...

Page 7: ...ATM Provisioning Slot Port Menu Tree 23 Figure 7 ATM Provisioning DS3 Menu Tree 24 Figure 8 Traffic Descriptor Menu Tree 25 Figure 9 VC VP Provisioning Menu Tree 26 Figure 10 Software Upgrade Menu Tre...

Page 8: ...nfiguration Menu 82 Figure 42 DS3 PSM Status Menu 84 Figure 43 DS3 CSM Status Screen 85 Figure 44 Line Card Status Screen 87 Figure 45 Port Status Screen 88 Figure 46 SPVC Status Screen 89 Figure 47 C...

Page 9: ...DS3 and Timing Provisioning Menu Options 47 Table 23 Framing Menu Options 49 Table 24 Primary Timing Menu Options 50 Table 25 Secondary Timing Menu Options 51 Table 26 ATM Provisioning Screen Shelf Sl...

Page 10: ...s 100 Table 62 Insert Cell Test Screen Fields 103 Table 63 Single Card Cell Generation Test Menu Options 106 Table 64 Performance Monitoring Menu Options 107 Table 65 DS3 Performance Monitoring Defini...

Page 11: ...ERAL This practice is an installation and maintenance guide for the ADTRAN Total Access 3000 DSLAM DS3 Primary Switch Module DS3 PSM Figure 1 illustrates the DS3 PSM P N 1181041L3 front panel Figure 1...

Page 12: ...System Manual P N 61181918L1 1 for more HDX system information The DS3 PSM installs into a single multiplexer slot slot A in a non redundant configuration or slots A and B in a redundant configuratio...

Page 13: ...U Reporting and managing of Quality of Service QoS is also supported The DS3 PSM also exercises synchro nized Performance Monitoring PM and provisioning between active and standby units APS The DS3 PS...

Page 14: ...e total length of the bus is limited to 20 meters 65 6 feet Figure 2 shows an MDE Link overview Figure 2 MDE Link Overview Primary Shelf The Primary Shelf acts as the gatekeeper for both management an...

Page 15: ...d have been installed and the ESMs have been installed and cabled to the DS3 PSM Perform the following steps to enable an ESM on an installed shelf 1 Log on to the Total Access system via the PCU 2 Se...

Page 16: ...nline to offline unit Local ATM switching capability Supports UBR rtVBR nrtVBR and CBR service types Provides UNI 4 0 and 3 1 interface compatibility Supports PNNI version 1 0 Provides Switched Perman...

Page 17: ...larms Loss Of Signal LOS and Out Of Frame OOF detected on the incoming DS3 signal causes an Alarm Indication Signal AIS to be substituted in all low speed tributaries AIS The DS3 PSM inserts AIS in bo...

Page 18: ...ards The DS3 PSM complies with UL 60950 NEBS Level 3 and GR 1089 CORE The DS3 PSM is to be installed in a restricted access location and in a Type B or E enclosure only This device complies with Part...

Page 19: ...ice Maintenance mode and no alarms have been detected DS3 remote alarm condition detected Local alarm or local and remote alarm condition detected TEST Off Yellow A test is not in progress A test is i...

Page 20: ...d CAUTION Electronic modules can be damaged by Electrostatic Discharge ESD When handling modules wear an antistatic discharge wrist strap to prevent damage to electronic components Place modules in an...

Page 21: ...on the ejector latch When the DS3 PSM first powers up self tests are performed Once the self tests are complete the status LEDs display the operational state of the module A stable configuration illum...

Page 22: ...modules identical A change in the Linked Provisioning status to either module is transferred to the other module causing both modules to always have the same Linked Provisioning status Therefore both...

Page 23: ...I Scrambler Enabled Disabled Disabled Maximum VCCs 1 8000 or 1 4096 32 Maximum VPCs 1 256 32 Maximum VPI Bits 0 8 8 Maximum VCI Bits 5 16 9 Physical Address User defined blank Neighbor IP Address User...

Page 24: ...NNI UNI Maximum VCCs 1 8000 or 1 4096 719 Maximum VPCs 1 256 0 Maximum VPI Bits 0 8 8 Maximum VCI Bits 5 16 16 Physical Address User defined 00000000000000 Neighbor Name User defined blank Neighbor IP...

Page 25: ...on that cannot be changed The information displayed in a read only field can be static or can be automatically updated by the DS3 PSM Read write Field A read write field displays information that when...

Page 26: ...e display CTRL Z Control and z This keyboard command is used to force the terminal menu display to the top level ESC Escape This keyboard command is used to clear partial input or returns to the previ...

Page 27: ...me Typing E displays the Enter Index of VC VP To Enable prompt A PVC will not pass data unless it has been enabled from this menu ENTER INDEX Enter the Index number for a corresponding PVC to display...

Page 28: ...his hot key is used to display the Search Through SPVC List Menu to search existing Loop ports or DS3 ports Alarms Screen F This hot key is used to display the first page of alarms L This hot key is u...

Page 29: ...VP List S This hot key is used to display the Search Through VC VP List Menu to select one of the following options Search for Loop Ports Search for DS3 Ports Search for MGMT Ports Search for TDs V Th...

Page 30: ...e 1 DS3 and Timing Status 2 Port Status 3 SPVC ATM Status 1 Configuration 2 Provisioning 3 Status 4 Alarms Main Menu 7 Protection Configuration Unit Name CLEI Code Part Number Serial Number Product Re...

Page 31: ...Provisioning DS3 5 ATM Provisioning MGMT Port 6 Traffic Descriptor Provisioning 10 MDE Link Configuration 9 Software Updgrade Menu 3 ATM Provisioning Port 1 Framing 2 Line Length meters 3 Primary Timi...

Page 32: ...licing 2 Default Input CDVT 3 Cell Rate CAC 4 CBR Overbooking 5 Cell Buffer CAC 6 rtVBR Overbooking 7 AIS RDI Generation 8 nrtVBR Overbooking 9 nrtVBR Sharing 10 UBR Sharing 11 CBR Class Scheduling 12...

Page 33: ...tion Token 3 Admin Weight CBR 4 Admin Weight rtVBR 5 Admin Weight nrtVBR 6 Admin Weight UBR 7 Service Classes 8 VP Connections Allowed 9 Allow SPVC Connections 10 Auto Address Setup 1 No Classes Suppo...

Page 34: ...Cell 1 Allow SVCs 2 Aggregation Token 3 Admin Weight CBR 4 Admin Weight RT VBR 5 Admin Weight NRT VBR 6 Admin Weight UBR 7 Service Classes 8 VP Connections Allowed 9 Allow SPVC Connections 10 Auto Ad...

Page 35: ...atmClpTransparentNoScr 6 atmNoClpNoScrCdvt 4 atmClpTagNoScr 1 No Policing 2 atmNoClpNoScr 3 atmClpNoTagNoScr 5 atmNoClpTagNoScr 6 atmNoClpNoScrCdvt 4 atmClpTagNoScr 2 atmNoClpScr 3 atmClpNoTagScr 1 N...

Page 36: ...ndpoint 2 Sh Sl Po DS3 MGMT 16 Tx SDU Size P Set Path PVC PVP N Set Name C Create PVC PVP N Next P Previous SRV CL VCI VPI SH SL PO Endpoint 2 VCI VPI SH SL PO Endpoint 1 Type Status Index C Create PV...

Page 37: ...7 6k 3 38 4k 1 Transfer Protocol 2 SCU to MUX Baud Rate 3 TFTP File Name 4 Start Transfer 5 Restore Card Factory Defaults and Reset 6 Restart Card with Latest Code App Software Rev App Code Chksum Boo...

Page 38: ...oopback 2 Insert Cells 1 Single Port Loopback 2 Daisy Chain 5 Dual Loopback 6 LIU Network Loopback 7 LIU Digital Local Loopback 8 LIU Analog Local Loopback 1 End to End 2 Segment 1 Endpoint 1 Remote O...

Page 39: ...3 Sev Erred Sec L 4 Loss of Sig Sec L 5 Code Violation P P 6 Code Violation CP P 1 Code Violation CP P 2 Errored Sec CP P 3 Sev Erred Sec CP P 4 Unavail Sec CP P 5 Sv Er Frame CP P 7 Errored Sec P P...

Page 40: ...6 Interval Duration 7 Cached Intervals 8 Scope 1 DS3 ATM Stats 2 MGMT ATM Stats 4 VC VP ATM Stats 3 Port ATM Stats Slot Port 5 ATM Monitor Sessions Enter Index N Next P Previous Name Scope Status Inde...

Page 41: ...een on page 32 2 Provisioning This option displays the Provisioning Menu on page 33 3 Status This option displays the DS3 PSM Status Menu on page 84 4 Alarms This option displays the CSM Alarms Screen...

Page 42: ...ld Description Unit Name This field displays the unit name of the DS3 PSM CLEI Code This field displays the CLEI code of the DS3 PSM Part Number This field displays the part number of the DS3 PSM Seri...

Page 43: ...helf Slot Port number are entered 4 ATM Provisioning DS3 This option displays ATM Provisioning Screen DS3 Port Menu on page 59 5 ATM Provisioning MGMT Port This option displays the ATM Provisioning Sc...

Page 44: ...ng Base menu This option displays the PNNI Switch Provisioning Base Menu on page 78 9 Software Upgrade Menu This option displays the Software Upgrade Menu on page 80 10 MDE Link Configuration This opt...

Page 45: ...tion This option is used to set and display the unique OAM identifier An OAM identifier is used as a point of origin to identify OAM cells Maximum Network VC VPs This field displays the maximum number...

Page 46: ...nc state This option displays the Invalid cells to exit Sync state value The value can be set to any number between 1 and 15 This option sets the number of bad invalid cells detected before the DS3 PS...

Page 47: ...t Bit Rate CBR 50 of 1 PCR real time Variable Bit Rate rtVBR 60 of 1 PCR non real time Variable Bit Rate nrtVBR 80 of 1 PCR Unspecified Bit Rate UBR 100 of 1 PCR Note The value 1 PCR is the cell arriv...

Page 48: ...nrtVBR Overbooking This option is used to set the nrtVBR Overbooking value to a number from 1 to 32767 9 nrtVBR Sharing This option is used to set the nrtVBR Sharing value to a number from 1 to 100 1...

Page 49: ...CAC Policing Options Menu Hot Keys Hot Key Description L This hot key is used to display the System Buffer CAC Policing Options Menu on page 37 P This hot key is used to display the Shelf Slot Port B...

Page 50: ...ed to control Default Input Cell Delay Variation Tolerance CDVT override 12 Override This option is used to control CBR Overbooking setting override 14 Override This option is used to control rtVBR Ov...

Page 51: ...to control nrtVBR Class Scheduling override 29 Override This option is used to control UBR Class Scheduling override Table 16 WAN Direction Network Buffer CAC Policing Options Menu Hot Keys Hot Key De...

Page 52: ...lt Input Cell Delay Variation Tolerance CDVT override 12 Override This option is used to control CBR Overbooking setting override 14 Override This option is used to control rtVBR Overbooking setting o...

Page 53: ...to control nrtVBR Class Scheduling override 29 Override This option is used to control UBR Class Scheduling override Table 18 Loop Direction Buffer CAC Policing Options Menu Hot Keys Hot Key Descripti...

Page 54: ...This option is used to control Default Input Cell Delay Variation Tolerance CDVT override 12 Override This option is used to control CBR Overbooking setting override 14 Override This option is used t...

Page 55: ...UBR Class Scheduling override Table 20 Shelf Slot Port Buffer CAC Policing Options Menu Hot Keys Hot Key Description L This hot key is used to display the System Buffer CAC Policing Options Menu on p...

Page 56: ...are shown in Table 21 Table 21 Alarms Provisioning Menu Options Option Description Function 1 Timing Alarm This option is used to enable or disable the Timing Alarm 2 Cell Delineation Alarm This opti...

Page 57: ...th as follows A value from 0 to 254 for short lengths A value from 255 to 64000 for long lengths Line Length represents the physical length of the DS3 coax connecting to the network and must be manual...

Page 58: ...3E Clock module P N 1181930L1 must be installed in Slot 1 of the Primary Total Access 3000 shelf Line Code This field displays the Line Code type The DS3 interface uses B3ZS as defined in ANSI T1 102...

Page 59: ...T MAP This option sets the DS3 framing to C Bit Direct Mapped 2 C BIT PLCP This option sets the DS3 framing to C Bit Physical Layer Convergence Protocol PLCP 3 M23 DIRECT MAP This option sets the DS3...

Page 60: ...ion Description Function 1 Bank Timing This option is used to set Bank Timing to one of the following values LOCAL LOOP PLCP EXT BITS B EXT BITS C LINECARD a value from 1 to 28 which corresponds to th...

Page 61: ...scription Function 1 Bank Timing This option is used to set Bank Timing to one of the following values NONE LOCAL LOOP PLCP EXT BITS B EXT BITS C LINECARD a value from 1 to 28 which corresponds to the...

Page 62: ...ach individual port can be placed in one of the following service states In Service In this state the DS3 PSM passes data and alarms are generated for error conditions Provisioning activation of test...

Page 63: ...lue 10 Maximum VPCs This option is used to set the maximum VPCs Virtual Path Connections value to a number from 1 to 256 The sum of the current Permanent Virtual Path PVP SVP SPVPs for this port canno...

Page 64: ...NNI Port Options Menu on page 55 17 Restore Factory Defaults This option is used to restore the provisioning options for the selected port to the following factory default values Port ID Service Mode...

Page 65: ...on token is number assigned to an outside link by the border nodes at the ends of the outside link The same number is associated with all uplinks and induced uplinks associated with the outside link I...

Page 66: ...ork operator 6 Admin weight UBR This option is used to set the Admin weight Unspecified Bit Rate UBR value to a number from 1 to 16777215 The administrative weight is used to indicate the relative des...

Page 67: ...to set the VPI value to a number from 0 to 255 3 VCI This option is used to set the VCI value to a number from 0 to 511 4 Addr Reg This option is used to enable or disable Address Registra tion 5 Auto...

Page 68: ...q Timer value to a number from 1 to 30 10 Get Req Timer This option is used to set the Get Req Timer value to a num ber from 1 to 30 11 Max Svpc Vpi This option is used to set the Max Svpc Vpi value t...

Page 69: ...ror conditions Out of Service Maintenance In this state the DS3 Port does pass data but alarms are suppressed Out of Service Unassigned In this state the DS3 Port is disabled The default state is Out...

Page 70: ...is used to set and display the alphanumeric Physical Address often the ATM address of the DS3 port 11 Neighbor Name This option is used to set and display the remote far end termination of the interfa...

Page 71: ...DS3 provisioning options to the following factory default values Service Mode Out of Service Maintenance Port Type NNI Scrambler Enabled Maximum VCCs 8192 Maximum VPCs 4096 Maximum VPI Bits 12 Maximum...

Page 72: ...s the service mode of the management port which is always In Service N A Port Type This field displays the Port Type UNI or NNI assigned to the port N A Maximum VCCs This field displays the maximum VC...

Page 73: ...Station can send SNMP messages as IP datagrams sent to UDP port 161 in order to access network management information concerning the operation of that system 11 CSM Linecard Channel VPI This option is...

Page 74: ...Port ID Service Mode In Service Port Type UNI Maximum VCCs 719 Maximum VPCs 0 Maximum VPI Bits 8 Maximum VCI Bits 16 Physical Address 00000000000000 Neighbor Name Neighbor IP Address 0 0 0 0 CSM Line...

Page 75: ...t keys are shown in Table 33 Table 32 Traffic Descriptor Screen Fields Field Description Index This field displays the Index assigned to the traffic descriptor Name This field displays the Name assign...

Page 76: ...or Screen on page 67 D This hot key is used to duplicate an existing traffic descriptor M This hot key is used to modify an existing traffic descriptor N This hot key is used to display the next page...

Page 77: ...ed and press ENTER 3 Select Provisioning and press ENTER 4 Select Traffic Descriptor Provisioning and press ENTER 5 Press C to display the Create Traffic Descriptor Screen 6 Using the options availabl...

Page 78: ...Constant Bit Rate rtVBR real time Variable Bit Rate nrtVBR non real time Variable Bit Rate UBR Unspecified Bit Rate 3 Type This option is used to select one of the following standard traffic descript...

Page 79: ...ype as either PVC or PVP SRV CL This field displays the Service Class assigned to the PVC defined by the traffic descriptor Endpoint 1 SH SL PO This field displays the shelf slot port location of the...

Page 80: ...nu ENTER INDEX Enter the Index number for a corresponding PVC to display the Detailed PVC Information Screen on page 71 which displays the details of that PVC G This hot key is used to display a speci...

Page 81: ...L the MGMT Port at Endpoint 1 accepts AAL0 or AAL5 AAL Encaps This field displays the selected type of AAL Encapsulation that is implemented for the MGMT Port at Endpoint 1 TX SDU This field displays...

Page 82: ...MBS cells This field displays the Maximum Burst Size MBS for the Fwd Traffic Descriptor cells Frame Discard This field displays whether Frame Discard is enabled or disabled for the Fwd Traffic Descri...

Page 83: ...t of available traffic descriptors type If the menu is used enter A assign prior to the traffic descriptor selection 7 Enter the VPI VCI information for each endpoint using the available options and t...

Page 84: ...o DS3 MGMT This option refers to Endpoint 1 and requires the PVC End point in the syntax of Shelf Slot Port or enter DS3 or MGMT If an endpoint is set to the Management port an additional option AAL T...

Page 85: ...ceding PVC Provisioning menu The VC VP Provisioning Create PVC PVP menu hot keys are shown in Table 39 11 VPI This option sets the VPI for Endpoint 2 and requires a numeric entry 0 to 255 when operati...

Page 86: ...tice 76 61181041L3 5A Table 39 VC VP Provisioning Create PVC PVP Menu Hot Keys Hot Key Description C This hot key is used to create a new PVC PVP N This hot key is used to set the VC VP name for a new...

Page 87: ...search the VC VP List for Loop Ports by entering the shelf slot port numbers and pressing ENTER 2 Search for DS3 Ports This option is used to search the VC VP List for DS3 Ports 3 Search for MGMT Por...

Page 88: ...own in Table 41 Table 41 PNNI Switch Provisioning Base Menu Options Option Description Function 1 Hierarchy depth This option displays the Hierarchy depth menu which contains the following options PNN...

Page 89: ...layed 4 Node ID This option is used to enter the Node ID in the format displayed 5 Peer group ID This option is used to enter the Peer group ID in the format displayed 6 Domain name This option is use...

Page 90: ...the following PCU to MUX baud transfer rates in Kilobytes 115 2K 57 6K 38 4K 3 TFTP Filename This option is used to input the name of the file to transfer 4 Start Transfer This option is used to star...

Page 91: ...v This field displays the boot software revision of the current software N A Boot Code Chksum This field displays the boot code checksum of the current software N A Download Status This field displays...

Page 92: ...nu Options Option Description Function 1 Shelf 1 This field displays Shelf 1 the Primary Shelf as either Shelf Present or Shelf Removed 2 Shelf 2 This field displays Shelf 2 as either Shelf Present or...

Page 93: ...is field displays the Shelf 3 link status as either Link Up or Link Down N A Shelf 4 Link Status This field displays the Shelf 4 link status as either Link Up or Link Down N A Shelf 5 Link Status This...

Page 94: ...46 Table 46 DS3 PSM Status Menu Options Option Description Function 1 DS3 and Timing Status This option displays the DS3 CSM Status Screen on page 85 2 Port Status This option displays the Line Card...

Page 95: ...the active loop timing APS Status This field displays the current Automatic Protection Switching APS status as one of the following Online Allow This setting indicates that the unit is online and allo...

Page 96: ...smit indicators Normal This indicates that data transmission is normal TLOS This indicates a DS3 Transmit Signal failure Rx Line Status This field displays the status of DS3 receive data stream There...

Page 97: ...d Table 49 Line Card Status Screen Hot Keys Hot Key Description N This hot key is used to display the next shelf in the MDE Link Configuration P This hot key is used to display the previous shelf in t...

Page 98: ...module in that slot Figure 45 Port Status Screen The Port Status Screen fields are shown in Table 50 Table 50 Port Status Screen Fields Field Description 1 8 These fields display the Signaling Framing...

Page 99: ...the status of the VC VP as ENABLED or DISABLED TYPE This field displays the type as either PVC or PVP SRV CL This field displays the Service Class assigned to the PVC defined by the traffic descripto...

Page 100: ...nt VCI value of the VC VP Endpoint 2 Table 52 SPVC Status Screen Hot Keys Hot Key Description ENTER INDEX Enter the Index number for a corresponding SPVC to view information for that SPVC N This hot k...

Page 101: ...M Alarms Screen The CSM Alarms screen fields are shown in Table 53 The CSM Alarms screen hot keys are shown in Table 54 Table 53 CSM Alarms Screen Fields Field Description Date This field displays the...

Page 102: ...41L3 5A Table 54 CSM Alarms Screen Hot Keys Hot Key Description F This hot key is used to display the first page of alarms L This hot key is used to display the last page of alarms N This hot key is u...

Page 103: ...u Options Option Description Function 1 DS3 Loopback Test This option displays the CSM Test Menu on page 94 2 PVC PVP Test This option displays the VC VP Test Screen on page 99 3 Single Card Cell Gene...

Page 104: ...backs and changes based upon loopback selections The Network side is to the left of the DS3 Line Interface Unit LIU The box to the right of the DS3 Framer is representative of the ATM engine The Local...

Page 105: ...est This test sends a loopback toward the network before the DS3 Framer 4 Local Payload Loopback This option is used to perform a Local Payload Loopback test This test sends a loopback toward the loop...

Page 106: ...m an LIU Digital Local Loopback test This test sends a loopback toward the loop ports at the digital side of the LIU 8 LIU Analog Local Loopback This option is used to perform an LIU Analog Local Loop...

Page 107: ...ype as either PVC or PVP SRV CL This field displays the Service Class assigned to the PVC defined by the traffic descriptor Endpoint 1 SH SL PO This field displays the shelf slot port location of the...

Page 108: ...g PVC to display the VC VP Test Screen on page 99 which is used for OAM loopback and cell insertion testing G This hot key is used to display a specific PVC page of the Created VC VP List N This hot k...

Page 109: ...reen options are shown in Table 60 Table 60 VC VP Test Screen Options Option Description Function 1 OAM LoopBack This option is used to display the OAM Loopback Test Screen on page 100 2 Insert Cells...

Page 110: ...VC VP as Enabled or Disabled TYPE This field displays the type as either PVC or PVP SRV CL This field displays the Service Class assigned to the PVC defined by the traffic descriptor Endpoint 1 Top Le...

Page 111: ...ard Endpoint 2 equipment 6 Reset OAM Loopback Stats This option is used to reset the OAM Loopback Statistics Endpoint1 N A OAM Tx LoopBack Req This field displays the number of OAM Transmit Loopback R...

Page 112: ...s for Endpoint 2 N A OAM Rx LoopBack Rsp This field displays the number of OAM Receive Loopback Responses for Endpoint 2 N A OAM LoopBack Passed This field displays the number of successful OAM Loopba...

Page 113: ...or Disabled TYPE This field displays the type as either PVC or PVP SRV CL This field displays the Service Class assigned to the PVC defined by the traffic descriptor Endpoint 1 Top Level SH SL PO This...

Page 114: ...Test Cells to the Network for Endpoint 1 Egress Rx This field displays the number of received Test Cells from the Local side for Endpoint 1 Egress Tx This field displays the number of transmitted Tes...

Page 115: ...initiated the system generates cells and checks for CRC errors when the cell returns Errored seconds and CRC errors are accumulated and displayed on the screen Figure 55 CSM Test Single Card Cell Gen...

Page 116: ...sy Chain This test creates multiple temporary PVCs that send the test pattern from the first port through each port to the last port and back again The cells are checked and counted on each end and in...

Page 117: ...ormance Monitoring Menu The Performance Monitoring menu options are shown in Table 64 Performance Monitoring definitions are listed in Table 65 Table 64 Performance Monitoring Menu Options Option Desc...

Page 118: ...ter value indicates a count of C bit Parity errors that have occurred during the accumulation period Errored Seconds P P This parameter indicates the number of seconds containing at least one of the f...

Page 119: ...An incoming Yellow Alarm indicates that far end equipment detected an SEF 4 AIS Alarm Indication Signal This parameter indicates the detection of an unframed signal with a 1s density of at least 99 9...

Page 120: ...on displays the DS3 CSM Far End Daily Menu on page 113 3 Total 24 Hour Period This option displays the Total 24 Hour Period screen 4 Total 24 Hour Period Far End This option displays the Total 24 Hour...

Page 121: ...n displays the DS3 CSM Daily Loss of Signal Sec Line screen which displays only line loss of signal second data in daily increments 5 Code Violation P P This option displays the DS3 CSM Daily Code Vio...

Page 122: ...ored second data in daily increments 10 Sev Erred Sec CP P This option displays the DS3 CSM Daily Severely Errored Second CP P screen which displays only C bit parity path severely errored second data...

Page 123: ...ption displays the DS3 CSM Far End Daily Severely Errored Second CP P screen which displays only C bit parity path severely errored second data in daily increments 4 Unavail Sec CP P This option displ...

Page 124: ...option displays the Port Performance DS3 Port Screen on page 115 2 MGMT ATM Stats This option displays the Port Performance MGMT Port Screen on page 116 3 Port ATM Stats This option displays the Port...

Page 125: ...Cells This field displays the number of user and OAM cells transmitted on the DS3 interface RxCells This field displays the number or user and OAM cells received on the DS3 interface before any polici...

Page 126: ...e MGMT Port Screen Fields Field Description TxCells This field displays the number of User and OAM cells transmitted on the Management interface RxCells This field displays the number or User and OAM...

Page 127: ...n Fields Field Description TxCells This field displays number of user and OAM cells transmitted on this interface RxCells This field displays the number or user and OAM cells received on this interfac...

Page 128: ...me assigned to the VC VP Endpoint 1 SH SL PO This fields displays the shelf slot port location of the VC VP Endpoint 1 VPI This fields displays the current VPI value of the VC VP Endpoint 1 VCI This f...

Page 129: ...iled PVC Information screen G This hot key is used to display a specific page of the Created VC VP List N This hot key is used to display the next page of the Created VC VP List P This hot key is used...

Page 130: ...H SL PO This field displays the shelf slot port location of the VC VP Endpoint 1 VPI This field displays the current VPI value of the VC VP Endpoint 1 VCI This field displays the current VCI value of...

Page 131: ...When a loss of cell delineation occurs this endpoint generates OAM AIS cells downstream If the PVC is terminated at the MPI port on the cell switch OAM RDI cells are generated upstream The AIS state...

Page 132: ...fore any policing actions are taken This count does not include any cells received with an OAM CRC 10 error Discarded CLP 0 This field displays the number of nonconformant cells discarded on this PVC...

Page 133: ...e status of the Monitor Session SCOPE This field displays the Monitor Session scope NAME This field displays the Name assigned to the Monitor Session Table 77 Monitor Session List Screen Hot Keys Hot...

Page 134: ...he Index number for a corresponding Monitor Session to display the details of that Monitor Session N This hot key is used to display the next page of the Monitor Session List P This hot key is used to...

Page 135: ...Menu Options Option Description Function N A Operational Status This read only field displays the operational status as online or offline 1 APS Lockout Status This option is used to allow or inhibit...

Page 136: ...er to Appendix A Warranty for further information SPECIFICATIONS Specifications for the DS3 PSM are detailed in Table 79 Table 79 Specifications Specification Description Environmental Operating Tempe...

Page 137: ...s support Customer and Product Service CAPS requests or further information ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre Sales Applications Post Sales Technical Assistan...

Page 138: ...Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806...