BZ001M056A
ADT
‐
DK300A/400A
Engraving
Machine
61
(5)
Press
,
the
system
asks
whether
clear
all
parameters,
as
shown
in
Fig.
9
‐
3;
press
[EOB]
again,
the
system
restores
the
default
parameters
and
restarts
automatically.
Fig.
9
‐
3
9.4.
Parameter
backup
and
restore
This
function
can
back
up
the
modified
parameters.
When
the
system
is
updated
or
initialized,
the
parameters
can
be
restored
to
avoid
setting
the
parameters
repeatedly.
The
backup
files
can
be
copied
to
other
engraving
system.
Therefore,
please
back
up
the
parameters
after
adjusting
and
restore
the
parameters
directly
in
the
new
machine.
The
parameter
backup
and
restore
method
is
described
below:
(1)
Select
the
edit
mode;
(2)
In
the
main
menu,
press
[Parameter]
to
enter
the
parameter
interface;
(3)
Press
the
[Management]
key
to
enter
the
management
parameter
interface;
(4)
Move
cursor
to
007
or
008,
and
select
corresponding
operation
menu;
(5)
Press
[EOB],
the
system
confirms,
and
performs
backup
or
restore
operation;
(6)
The
backup
operation
will
generate
the
SYSCONF.BAK
file
in
the
root
directory
of
disk
D.
Please
save
this
file
for
backup
in
the
future.
Summary of Contents for ADT-DK300A
Page 66: ...BZ001M056A ADT DK300A 400A Engraving Machine 57 ...
Page 160: ...BZ001M056A ADT DK300A 400A Engraving Machine 151 11 2 3 Digital output interface XS6 ...
Page 166: ...BZ001M056A ADT DK300A 400A Engraving Machine 157 11 3 2 Power connection diagram ...
Page 167: ...BZ001M056A ADT DK300A 400A Engraving Machine 158 11 3 3 Servo drive connection diagram ...
Page 168: ...BZ001M056A ADT DK300A 400A Engraving Machine 159 11 3 4 Step connection diagram ...