BZ001M056A
ADT
‐
DK300A/400A
Engraving
Machine
96
electric
cabinet
door
and
similar
sensitive
occasions.
If
there
are
several
insecure
places,
please
connect
the
signals
in
parallel
to
safety
signal
test
pin
of
the
system.
Considering
the
convenience
of
maintenance,
safety
signals
are
checked
only
when
the
system
starts
processing,
and
won’t
prompt
in
idle
state.
067
Pressure
Signal
ELevel
068
ChuckSignal
ELevel
Range
:
0~1
Unit
:
LOGIC
VOLTAGE
LEVEL
Authority
:
Operation
admin
or
higher
Default
:
0
Effective
time
:
Instant
Note
:
Set
the
effective
voltage
level
of
system
air
pressure
alarm;
set
the
effective
voltage
level
of
system
chuck
alarm.
Both
air
pressure
alarm
and
emergency
stop
alarm
are
effective
globally;
the
detection
ports
of
air
pressure
alarm
and
chuck
alarm
are
set
in
port
parameters.
069
OilPressure
Open(min)
070
OilPressure
Keep(sec)
071
OilPressureOut
Freq(Hz)
072
OilInspect
ELevel
Range
:
0~
10000
1~10000
0~100
0,~
1
Unit
:
Min
Sec
Hz
LOGIC
VOLTAGE
LEVEL
Authority
:
Operation
admin
or
higher
Default
:
0,
1,
0,
0
Effective
time
:
Instant
Note
:
Set
the
system
lubricating
function.
Oil
pressure
timing
open
parameter
controls
the
lubrication
timing
function,
0
is
to
turn
off
the
lubrication,
non
‐
zero
is
to
turn
on
the
lubrication
port
after
the
time
specified
by
timing
parameters
(min);
the
oil
pressure
hold
time
sets
the
hold
time
of
output
lubrication
port
(unit:
second),
oil
control
frequency
is
to
control
the
lubrication
signal
output
mode,
0
is
the
jog
mode,
non
‐
zero
is
the
time
to
control
the
Summary of Contents for ADT-DK300A
Page 66: ...BZ001M056A ADT DK300A 400A Engraving Machine 57 ...
Page 160: ...BZ001M056A ADT DK300A 400A Engraving Machine 151 11 2 3 Digital output interface XS6 ...
Page 166: ...BZ001M056A ADT DK300A 400A Engraving Machine 157 11 3 2 Power connection diagram ...
Page 167: ...BZ001M056A ADT DK300A 400A Engraving Machine 158 11 3 3 Servo drive connection diagram ...
Page 168: ...BZ001M056A ADT DK300A 400A Engraving Machine 159 11 3 4 Step connection diagram ...