BZ001M056A
ADT
‐
DK300A/400A
Engraving
Machine
93
Negative
Home
direction
is
valid
in
mechanical
home
mode,
that
is,
the
system
scans
the
home
signal
direction
of
the
machine
in
the
home
process.
054
Circle
InpUnit(mm)
Range
:
0~1
Unit
:
mm
Authority
:
Operation
admin
or
higher
Default
:
0.2
Effective
time
:
Instant
Note
:
Set
the
arc
interpolation
equivalent
If
this
value
is
too
small,
the
arc
has
higher
approximation
accuracy,
but
the
computation
will
be
too
high,
making
the
pause
during
processing
obvious
and
affecting
the
processing
effect.
055
G73(M)LoopObligate(mm)
056
G83(M)LoopObligate(mm)
Range
:
0.1~100
Unit
:
mm
Authority
:
Operation
admin
or
higher
Default
:
2.000
Effective
time
:
Instant
Note
:
Set
the
tool
retracting
amount
after
Q
is
fed
in
G73
and
G83
instructions;
this
parameter
(default:
2mm)
is
set
according
to
actual
chip
removal
effect.
057
ArcSpeedUpVal
Range
:
0&1
Unit
:
Authority
:
Operation
admin
or
higher
Default
:
1
Effective
time
:
Instant
Note
:
Set
arc
speed
processing
mode
As
for
arc
split,
0
is
to
interpolate
through
time
split
arc,
and
1
is
to
interpolate
through
step
split
arc.
Summary of Contents for ADT-DK300A
Page 66: ...BZ001M056A ADT DK300A 400A Engraving Machine 57 ...
Page 160: ...BZ001M056A ADT DK300A 400A Engraving Machine 151 11 2 3 Digital output interface XS6 ...
Page 166: ...BZ001M056A ADT DK300A 400A Engraving Machine 157 11 3 2 Power connection diagram ...
Page 167: ...BZ001M056A ADT DK300A 400A Engraving Machine 158 11 3 3 Servo drive connection diagram ...
Page 168: ...BZ001M056A ADT DK300A 400A Engraving Machine 159 11 3 4 Step connection diagram ...