8–1
S E C T I O N 8
Event Log
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
General Information
♦
Central Station Reporting
♦
Alarm Panel Logging
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
General Information
This section provides the additional event log entries that are added to the alarm panel when
a VistaKey is connected. Below is a list of the events sent to the central station (CS) and the
events logged into the alarm panel.
Central Station Reporting
The following list contains all additional events that may be reported to the CS. The entires
are grouped by event type. Note that event reporting can be enabled via the Access Dialer
Enables (described in the Programming section of this manual).
ACS Alarms
Event
Code
Specifier
Duress Access Grant
124
User #
Duress Egress Grant
125
User #
Door Forced Open/Restore
423
DSM Zone #
ACS Troubles
Event
Code
Specifier
AC Loss at Module/Restore*
342
DSM Zone #
Door Propped/Restore
426
DSM Zone #
DSM Trouble/Restore
427
DSM Zone #
RTE Trouble/Restore
428
DSM Zone #
* If a module experiences a loss of power or if the address switch on a VistaKey
module is changed to an improper address, the panel logs an ACLO MOD (AC Loss
Module) event and the AC Loss will be reported. If this event is logged and power is
applied to the module, check that the module’s address switch is set to the proper
address.
ACS Bypasses
Event
Code
Specifier
Access Point Bypass/Restore
577
DSM Zone # (Door Lock Is Open)
ACS System
Event
Code
Specifier
Module Reset
339
DSM Zone # (On Power-up)
Test Entry/Exit
607
DSM Zone #