At the “Exit Event?” prompt, enter 06 for Egress Grant.
•
At the “Access Point?” prompt, specify the access point at which the Egress Grant
must take place.
•
At the “Exit Action?” prompt, enter the code for the desired exit action (i.e., 21 for
Arm-Away). A listing of the Action Codes is provided in Table 5-1: Action Codes. The
following rules apply to the selected exit action:
The action only occurs when the above exit event occurs at the access point selected
and the card triggering the event is assigned to the access group being programmed.
Actions that arm or disarm partitions are only performed if the VISTA user
assigned to the card is assigned to the partitions selected.
Actions that grant access to access points will only be performed if the card has
access to these access points.
Actions that change the state (bypass, lock, protect, exit only) of access points are
only performed if the VISTA user assigned to the card is assigned to the partition to
which the access points are assigned.
b. To assign the action on exit to a cardholder, use the procedures provided in
“Performing Access Control Card Functions” described later in Section 6: User
Commands. When setting up the cardholder, observe the following:
•
At the “ACS Event?” prompt, enter 06 for Egress Grant.
•
At the “Access Point?” prompt, specify the access point at which the Egress Grant
must take place.
•
At the “Action?” prompt, enter the code for the desired exit action (i.e., 21 for arm-
Away). A listing of the Action Codes is provided in Table 5-1: Action Codes. If the
action selection requires a partition or other specifier, a prompt requests the
partition or other specifier. The following rules apply to the selected exit action:
Actions that arm or disarm partitions are only performed if the VISTA user
assigned to the card is assigned to the partitions selected.
Actions that grant access to access points will only be performed if the card has
access to these access points.
Actions that change the state (bypass, lock, protect, exit only) of access points are
only performed if the VISTA user assigned to the card is assigned to the partition to
which the access points are assigned.
The system has been set up for the Momentary Exit function, which performs the action you
specified when the group or cardholder exits. To use the function, the access group member
or cardholder energizes the switch. In response, the reader at the access point becomes an
exit reader for 15 seconds, during which time a card swipe causes the exit action to take
place.
Access Dialer Enables
When the VistaKey is installed with an alarm system, the system defaults are set so that the
system does not send reports to the central station for the following event categories:
•
ACS Troubles
•
ACS Bypasses
•
ACS System (i.e., ACS module reset, entry/exit test)
•
ACS Alarms