Section 5 - Programming
5–15
Setting Up Access Point Programming Options for Each VistaKey Module
Access point options for the VistaKey module(s) are set using Access Point Programming. To
reach Access Point Programming, enter #93 Menu Mode Programming and press the [0]
key until the following prompt is displayed.
Access Point Pgm
1=Yes 0=No
Press 1 or 0 to select Access Point Programming or to bypass Access
Point Programming.
If you press 1, the keypad displays the following prompt.
If you press 0, the keypad advances to Access Group Programming.
ENTER ACS PT#
01-15, 00=Quit
01
Enter a number from 01 to 15 for the access point number to be
programmed; or 00 to Quit Access Point Programming. The number
entered here for the access point number is the setting of the
VistaKey address switch (1 through 9 = 01 through 09, A=10, B=11,
C=12, D=13, E=14, or F=15).
Press [
✲
] to accept the entry.
If you have finished programming the access points, enter 00. The
alarm control panel advances to Access Group Programming.
If you enter a number from 01 through 15, the keypad displays the
following prompt.
↓
Access Point Number
01 DSM CONFIG
NORM OPEN
0
Enter 1 digit for the DSM zone (VistaKey zone A) configuration. The
configuration entered must be the DSM status when the door
(access point) is closed. Acceptable 1-digit entries are as follows:
0 = normally open
1 = normally closed
2 = EOLR normally open
3 = EOLR normally closed
Press [
✲
] to accept the entry.
↓
Access Point Number
01 DOOR OPN TIME
3s
2
The door open time is the amount of time that the door-locking
device is kept in the unlocked (open) status following a valid card
swipe at the card reader or RTE (if enabled), unless a relatch
condition occurs. Enter 1 digit (0 to 7) for the door strike relay
duration in seconds.
0 = 1 second
4 = 5 seconds
1 = 2 seconds
5 = 10 seconds
2 = 3 seconds
6 = 15 seconds
3 = 4 seconds
7 = 30 seconds
Press [
✲
] to accept the entry.
↓
Access Point Number
01 ALARM TIMEOUT
10s
0
Enter 1 digit for the door alarm timeout value. The timer for alarm
timeout starts at the end of the door open time defined above;
therefore, the total amount of time before a zone fault is issued is
the amount set for the door open time plus the amount of time
entered for this prompt (see figure below). If the access point is still
open when the timeout value entered has expired, a zone fault
(alarm timeout) is reported to the VISTA panel and a Door Propped
event is logged.