Section 5 - Programming
5–19
↓
Access Point Number
01TRIG OFF TIME
1s
0
Enter 1 digit for the time, in seconds, that the trigger is to remain
de-energized if its mode is set as repeating. This is the time that
makes up the “OFF” time of a repeating cycle. Acceptable 1-digit
entries are as follows:
0 = 1 sec.
4 = 5 sec.
1 = 2 sec.
5 = 10 sec.
2 = 3 sec.
6 = 15 sec.
3 = 4 sec.
7 = 30 sec.
Press [
✲
] to accept the entry.
01 TRIG ON TIME
1s
0
Enter 1 digit for the time, in seconds, that the trigger is to remain
energized if its mode is set as one-shot. If the mode is set as
repeating, this is the time that makes up the “ON” time of a
repeating cycle. Acceptable 1-digit entries are as follows:
0 = 1 sec.
4 = 10 sec.
1 = 2 sec.
5 = 30 sec.
2 = 3 sec.
6 = 1 min.
3 = 5 sec.
7 = 2 min.
Press [
✲
] to accept the entry.
ACS GRP? 1 2 3 4 5 6 7 8
HIT 0-8
x x x x x x x x
Select the access groups that will be allowed entry or egress through
this access point when their respective access group is enabled via
scheduling. Note that cardholders with executive privileges enabled
have access to all access points regardless of this setting. Also note
that cardholders with expired cards will not have access to any
access point, regardless of this setting.
Press 0 to toggle all access groups on or off; or press keys 1-8 to
toggle the letter “x” under the access group numbers on or off.
Press [
✲
] to accept the entry.
RDR CONFIG
WEIGAND
0
This prompt accepts 0 (Weigand) or 1 (Clock/Data). The ADEMCO
reader is a Weigand configuration (format) reader.
Press 0 for a Weigand reader configuration.
Press [
✲
] to accept the entry.
↓
Access Point Number
01 RDR POSITION
Entry
0
Enter the reader position as either ENTRY or EXIT. This is
important for EXIT EVENT and ENTRY EVENT event/action
selection during Access Group Programming and determines how
associated events are logged and reported (e.g., Access Grant,
Egress Grant).
Press 0 or 1 to select if the reader is an entry reader (0) or an exit
reader (1).
Press [
✲
] to accept the entry.
The system will return to the “ENTER ACS PT#” prompt.
Summary of Contents for VistaKey-SK
Page 2: ......
Page 6: ...vi...
Page 8: ...viii...
Page 40: ...VistaKey Installation Guide 4 10...
Page 107: ......
Page 108: ...165 Eileen Way Syosset New York 11791 Copyright 2000 PITTWAY CORPORATION l K4005 6 00...