Section 5 - Programming
5–3
•
When you use action codes 60 (AP Exit Only), 66 (AP Group Exit Only), or 72 (AP Partition
Exit Only), these actions disable the entry reader at the access point. The reader will remain
disabled until a command is received (via a keypad command or event) to protect the access
point.
•
The time-driven events described here are the same as those explained in your alarm panel
Installation and Setup Guide, except that additional actions have been added. If you are
already using time-driven events, make certain that the first Timed Event # you use is after the
last number you have already assigned; otherwise you will overwrite your existing time-driven
events.
•
At the end of a time window controlling an access point, the access point will revert to the
protect mode.
Fill out the Time-Driven Events Worksheet (near the end of this section) using the steps
outlined below:
As an aid to understanding the procedures for filling out the Time-Driven Events Worksheet,
assume that you want to enable access groups 1 and 2 from 08:00 AM to 05:00 PM (set via
time window 01) on Monday through Friday. As you perform the following steps, examples are
provided for filling out the worksheet.
1. Enter the Action No. listed in Table 5-1: Action Codes for the action desired.
Example: Enter Action No. 77 for Access Group Enable.
Days
Timed
Event #
Action
No.
Action
Name
Action
Specifier
Time
Window
Activation
Time
M
T
W
T
F
S
S
H
1
77
2
2. Enter the Action Name listed in Table 5-1: Action Codes for the action number.
Example: Enter ACS Grp Enbl for Access Group Enable.
Days
Timed
Event #
Action
No.
Action
Name
Action
Specifier
Time
Window
Activation
Time
M
T
W
T
F
S
S
H
1
77
ACS Grp Enbl
2
3. Enter the Action Specifier that corresponds to the description in Table 5-1:
Action Codes.
Example: Enter 1 and 2 for access groups 1 and 2.
Days
Timed
Event #
Action
No.
Action
Name
Action
Specifier
Time
Window
Activation
Time
M
T
W
T
F
S
S
H
1
77
ACS Grp Enbl
1 2
2
4. Enter the Time Window number that corresponds to the time window
(previously programmed) that should trigger the action.
Example: Assume that time window 01 has a start time of 08:00 AM and end time of 05:00
PM. Enter 01 for time window 1.
Days
Timed
Event #
Action
No.
Action
Name
Action
Specifier
Time
Window
Activation
Time
M
T
W
T
F
S
S
H
1
77
ACS Grp Enbl
1 2
01
2
Summary of Contents for VistaKey-SK