4-15
Using the SCSISelect Utility to Manage Arrays
Bootable Array
To create a bootable array:
1
From the Main menu, select array, press Enter, then press B for
the Bootable function.
2
Select Mark Bootable and press Enter.
Note:
Mark Bootable gives boot priority to the array
regardless of the SCSI ID priority.
A
B
will appear next to the drive ID to indicate it as bootable.
Check Point
HostRAID has a check point feature that enables you to exit the
SCSISelect utility when an operation (for example, Verify, or
Rebuild) is in progress. The HostRAID driver will continue the
operation where SCSISelect left off and SCSISelect will continue the
operation where the HostRAID driver left off if an operation was
started from the driver.