4-5
Using the SCSISelect Utility to Manage Arrays
■
Dead—
One drive in a RAID 0 array is in failed state or
missing.
■
Building—
the drive is a target of an ongoing Rebuild
operation
■
Verifying—
checking the data integrity of redundant
data stored on fault-tolerant arrays
Viewing Array
To view an array, select the array and press Enter. A detailed view
of the hard drives will appear. From this window you can see the
status of the individual hard drives. The status you might see are:
■
Optimal—
no defect
■
Building—
the drive is a target of an ongoing Rebuild operation
■
Verify—
checking the data integrity of redundant data stored
on fault-tolerant arrays
Missing drive information indicates that a member is missing
and the array is not optimal
Exiting the SCSISelect Utility
To exit SCSISelect:
1
Press Esc until a message prompts you to exit (if you changed
any settings, you are prompted to save the changes before you
exit).
2
At the prompt, select Yes to exit. If prompted, press any key to
restart the computer. Any changes you made in SCSISelect takes
effect after the computer restarts.
Creating Arrays
Before creating the array, make sure the disks for the array are
connected and installed in your system, then follow these steps:
1
Start SCSISelect (Ctrl-A).
2
Select Configure/View HostRAID Settings.
U320 UG.book Page 5 Tuesday, September 23, 2003 1:47 PM