231
Demand Scrubbing: A memory error-correction scheme where the
processor writes corrected data back into the memory block from
where it was read by the processor.
Patrol Scrubbing: A memory error-correction scheme that works in the
background looking for and correcting resident errors.
Throttling - Closed Loop/Throttling - Open Loop: Throttling improves
reliability and reduces power in the processor by automatic voltage
control during processor idle states. If Enabled, the following items will
appear:
•
Hysteresis Temperature (For Closed Loop only) - Temperature
Hysteresis is the temperature lag (in degrees Celsius) after the set
DIMM temperature threshold is reached before Closed Loop
Throttling begins.
•
Guardband Temperature (For the Closed Loop only) - This is the
temperature which applies to the DIMM temperature threshold.
Steps are in 0.5 °C increments. The default is [006]. Press "+" or "-"
on your keyboard to change this value.
•
Inlet Temperature - This is the temperature detected at the chassis
inlet. Steps are in 0.5 °C increments. The default is [070]. Press "+"
or "-" on your keyboard to change this value.
•
Temperature Rise - This is the temperature rise to the DIMM
thermal zone. Steps are in 0.5 °C increments. The default is [020].
Press "+" or "-" on your keyboard to change this value.
•
Air Flow - This is the air flow speed to the DIMM modules. Each
step is one mm/sec. The default is [1500]. Press "+" or "-" on your
keyboard to change this value.
•
Altitude - This feature defines how many meters above or below
sea level the system is located.
•
DIMM Pitch - This is the physical space between each DIMM
module. Each step is 1/1000 of an inch. The default is [400]. Press
"+" or "-" on your keyboard to change this value.
Summary of Contents for AB460 F1
Page 1: ...AB7000 Series User Guide ...
Page 14: ...xiv ...
Page 21: ...1 Document Description ...
Page 24: ...1 Document Description 4 ...
Page 25: ...2 Chassis Enclosure ...
Page 37: ...17 Figure 2 8 Enclosure Installed into Rack ...
Page 111: ...3 Server Blades Setup and Installation ...
Page 121: ...101 Figure 3 60 Card Installation ...
Page 171: ...151 4 DIMMs system memory 5 Airflow Deflector 6 CPU Heatsinks 7 Top Cover Item Description ...
Page 280: ...3 Server Blades Setup and Installation 260 ...
Page 281: ...4 Networking Switch Modules ...
Page 573: ...5 Acer Smart Blade Manager ...
Page 600: ...5 Acer Smart Blade Manager 580 ...
Page 601: ...Appendix A Troubleshooting ...
Page 616: ...Appendix A Troubleshooting 596 ...