Communication
88
0x16
Parameter address
impermissible
Illegal value or value that is not
supported for the attribute, number of
elements, parameter number or sub-
index, or a combination
0x17
Illegal format
Write request: Illegal format or format of
parameter data that is not supported
0x18
Number of values inconsistent
Write request: Number of values of
parameter data does not match number
of elements at the parameter address
0x19
DO nonexistent
Request to DO, which does not exist
0x65…
0xFF
Manufacturer-specific
–
0x65
Vendor-specific error
Vendor-specific error
0x66
Request not supported
Request not supported
0x67
Communication error
Request cannot be completed because
of communication error
0x6F
Time-out error
Request aborted due to time-out
0x78
PZD map failure
Parameter cannot be mapped to PZD
(size mismatch or non-existent)
0x79
PZD memory failure
Parameter cannot be mapped to PZD
(out of memory)
0x7A
Multiple PZD map
Parameter cannot be mapped to PZD
(multiple PZD write)
0x8C
Set torque mode error
Cannot change mode to TORQUE
(frequency is used)
0x90
Illegal Request ID
The request ID of the response is illegal
Summary of Contents for RETA-02
Page 1: ...ABB Drives User s Manual Ethernet Adapter Module RETA 02 ...
Page 2: ......
Page 4: ......
Page 6: ...Safety instructions 6 ...
Page 10: ...Table of contents 10 ...
Page 14: ...Introduction 14 ...
Page 30: ...Mechanical installation 30 ...
Page 32: ...Electrical installation 32 ...
Page 42: ...Drive configuration 42 ...
Page 48: ...Network configuration 48 ...
Page 50: ...Master configuration 50 ...
Page 58: ...Communication profiles 58 11 to 15 Drive specific Bit Name Value STATE Description ...
Page 68: ...Communication profiles 68 ...
Page 106: ...Diagnostics 106 ...
Page 111: ......