Communication profiles
56
7 RESET
0
⇒
1 Fault reset if an active fault exists. Proceed to
SWITCH-
ON INHIBIT.
Note:
This bit is effective only if the fieldbus interface is
set as the source for this signal by drive parameters.
0
(Continue normal operation)
8 INCHING_1
Inching 1. (Not supported by all drive types)
9 INCHING_2
Inching 2. (Not supported by all drive types)
10 REMOTE_
CMD
1
Fieldbus control enabled.
0
Control Word <> 0 or Reference <> 0: Retain last Control
Word and Reference.
Control Word = 0 and Reference = 0: Fieldbus control
enabled.
11
to
15
Drive specific
Bit Name
Value
Proceed to
STATE/Description