Network configuration
44
IP settings configuration
Start
End
DIP
switches
= 0?
Use
DHCP?
DHCP
server
timeout?
Bus config
parameters
<> 0?
Configuration
received?
Use stored
settings
Use configuration
from DHCP server
Use 192.168.0.xxx
(xxx = DIP setting)
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Wait for config
through Gleaning or
DCP protocols