Communication
81
Table 15. ErrorCode1 with PNIORW decoding
Read
block is used in read requests and responses.
Write
block is
used in write requests and responses. The request consists of
Error class
Meaning
Error code
0 … 9
(Reserved)
10 (0x0A)
Application
0 = Read error
1 = Write error
2 = Module failure
3 … 7 = Reserved
8 = Version conflict
9 = Feature not supported
10 … 15 = User-specific
11 (0x0B)
Access
0 = Invalid index
1 = Write length error
2 = Invalid slot
3 = Type conflict
4 = Invalid area
5 = State conflict
6 = Access denied
7 = Invalid range
8 = Invalid parameter
9 = Invalid type
10 … 15 = User-specific
12 (0x0C)
Resource
0 = Read constraint conflict
1 = Write constraint conflict
2 = Resource busy
3 = Resource unavailable
4 … 7 = Reserved
8 … 15 = User-specific
13 … 15
User-specific
x x x x x x x x
MSB
LSB
Summary of Contents for RETA-02
Page 1: ...ABB Drives User s Manual Ethernet Adapter Module RETA 02 ...
Page 2: ......
Page 4: ......
Page 6: ...Safety instructions 6 ...
Page 10: ...Table of contents 10 ...
Page 14: ...Introduction 14 ...
Page 30: ...Mechanical installation 30 ...
Page 32: ...Electrical installation 32 ...
Page 42: ...Drive configuration 42 ...
Page 48: ...Network configuration 48 ...
Page 50: ...Master configuration 50 ...
Page 58: ...Communication profiles 58 11 to 15 Drive specific Bit Name Value STATE Description ...
Page 68: ...Communication profiles 68 ...
Page 106: ...Diagnostics 106 ...
Page 111: ......