5.3.2 States and actions
This module contains a number of predefined states and actions that are
consistently used throughout the FlexMT. If needed, new values can be added.
However, do not remove existing values, as they are used in the FlexMT core
functionality.
Examples for predefined values are:
•
Predefined machine checks/waits:
DOOR_OPENED, PREPICK_OK, LOAD_SUB_OK, LOAD_MAIN_OK,
UNLOAD_SUB_OK, UNLOAD_MAIN_OK, HOME_POSITION_OK
•
Predefined machine actions:
CLOSE_CHUCK_MAIN, CLOSE_CHUCK_SUB, CLOSE_DOOR,
OPEN_CHUCK_MAIN, OPEN_CHUCK_SUB, PREPARE_LOAD_MAIN,
PREPARE_LOAD_SUB, PREPARE_UNLOAD_MAIN,
PREPARE_UNLOAD_SUB, OPEN_DOOR, CYCLE_START, INIT_MACHINE,
STOP_MACHINE
96
3HAC051768-001 Revision: -
© Copyright 2014-2014 ABB. All rights reserved.
5 Robot program
5.3.2 States and actions