Identify the valves (F) according to figure below.
Valve location for deburring units
•
Disconnect the pneumatic connections and the two M4 screws, placed
underneath, holding the valve.
•
Replace the valve with a new one.
•
Mount the air cleaning box in reverse order, make sure the air cleaning box
connects correct to the pins placed in the FlexMT frame.
CAUTION
If there are any changes in position/design between the new and old unit the
robot positions need to be updated.
CAUTION
Run system at slow speed for the first cycles to ensure the air cleaning box is
in correct position.
188
3HAC051768-001 Revision: -
© Copyright 2014-2014 ABB. All rights reserved.
8 Repair
8.9.2 Exchange of valves
Continued