7.5.2 Filter cartridge replacement
What: Replace filter cartridge MS6-LFP-E
When: Depending on quality of the compressed air, generally 1-2 times/year, or
when air flow becomes to low.
How: Exhaust the unit. Push the unlocking slide in the direction of the arrow. Turn
the filter bowl in an anti-clockwise direction as seen from below. Pull the filter bowl
away from the unit. Turn the filter plate in an anti-clockwise direction. Replace the
filter cartridge if the pores are dirty. Grasp the filter cartridge only at the lower end
when it is new. Fit the individual parts again in the reverse sequence. The following
checks must then be made: The locking pinof the filter bowl must face the large
recess in the housing. The unlocking slide must be heard to clip into place when
the end stop is reached.
Cleaning; Use only the following cleaning agents: Water or soap suds (max. +60
°C), or petroleum ether (free of aromatic compounds).
Service unit - Open filter housing
Continues on next page
3HAC051768-001 Revision: -
155
© Copyright 2014-2014 ABB. All rights reserved.
7 Maintenance
7.5.2 Filter cartridge replacement
Summary of Contents for FlexMT
Page 1: ...Product manual FlexMT ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 236: ...This page is intentionally left blank ...
Page 242: ...This page is intentionally left blank ...
Page 244: ......
Page 245: ......