13.2.2 Operation ABB ACS355
13.2.2.1 Key functions
ABB Inverter display
1. LCD display – Divided into five areas:
•
a. Upper left – Control location:
-
LOC: drive control is local, that is, from the control panel
-
REM: drive control is remote, such as the drive I/O or fieldbus.
•
b. Upper right – Unit of the displayed value.
•
c. Center – Variable; in general, shows parameter and signal values, menus
or lists. Shows also fault and alarm codes.
•
d. Lower left and center – Panel operation state:
-
OUTPUT: Output mode
-
PAR: Parameter mode
-
MENU: Main menu.
-
FAULT: Fault mode.
•
e. Lower right – Indicators:
-
FWD (forward) / REV (reverse): direction of the motor rotation
-
Flashing slowly: stopped
-
Flashing rapidly: running, not at setpoint
-
Steady: running, at setpoint
-
SET: Displayed value can be modified (in the Parameter and Reference
modes).
2. RESET/EXIT – Exits to the next higher menu level without saving changed values.
Resets faults in the Output and Fault modes.
3. MENU/ENTER – Enters deeper into menu level. In the Parameter mode, saves
the displayed value as the new setting.
Continues on next page
3HAC051768-001 Revision: -
211
© Copyright 2014-2014 ABB. All rights reserved.
13 Appendix A: Configuration
13.2.2.1 Key functions
Summary of Contents for FlexMT
Page 1: ...Product manual FlexMT ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 236: ...This page is intentionally left blank ...
Page 242: ...This page is intentionally left blank ...
Page 244: ......
Page 245: ......