8.4.2 Exchange of smart camera
Change of camera shall be performed with as little impact as possible on existing
teach-In. Use the following procedure:
CAUTION: Safely shut the power to the FlexMT down and lock against accidental
turn-on.
•
Loosen the three cables connecting the smart camera
•
Loosen the four screws holding the camera mounting plate. Preferably use
a magnetic tool. See sketch below for identifying the location.
Location of smart camera mounting plate screws (view from below)
Location of smart camera mounting plate screws (view from side)
•
Remove camera from camera mounting plate and replace by new camera.
•
Move lens from the old smart camera to the new smart camera. Follow the
procedure for exchange of the camera lens.
•
Assemble camera mounting plate into FlexMT frame. Do not tighten screws
firmly yet.
•
Attach the three cables connecting the smart camera
•
Turn power to the FlexMT on.
•
Restore PickMT backup to the new smart camera
Continues on next page
172
3HAC051768-001 Revision: -
© Copyright 2014-2014 ABB. All rights reserved.
8 Repair
8.4.2 Exchange of smart camera
Summary of Contents for FlexMT
Page 1: ...Product manual FlexMT ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 236: ...This page is intentionally left blank ...
Page 242: ...This page is intentionally left blank ...
Page 244: ......
Page 245: ......