8.9.2 Exchange of valves
The valves controlling the deburring/grinding units are located below the statistic
outlet, next to the valves controlling the air cleaning nozzles. One or more valve
modules (Festo) can be exchanged by the following procedure:
•
Pull the statistic outlet to outer position.
•
Remove the protective cover over the valves (G).
Air cleaning box valve section cover
•
Disconnect the pneumatic connections that connects the valves to FlexMT.
•
Disconnect the electrical connection to the distributor box.
•
Pull the two bayonet fastenings, placed in front of the air cleaning box, and
twist them 90°.
Bayonet fastenings holding the air cleaning box in place.
•
Drag the air cleaning box out of FlexMT.
Continues on next page
3HAC051768-001 Revision: -
187
© Copyright 2014-2014 ABB. All rights reserved.
8 Repair
8.9.2 Exchange of valves