II K 4-40
Overview of Software
4.5.11 Signal definitions
Signal "At Set Point"
Speed reference reached.
Speed actual value
Speed Act (5.05)
correspondes
to speed reference value before ramp generator
Ramp In Act (5.33)
. The deviation between both is
less than ±1,56% (1/64) of parameter maximum speed
Max Speed (1.06)
. Signal At Set Point is independent
on ON and RUN command.
Signals "Speed > Lev1“ / „Speed > Lev2“
Speed Level reached. Speed actual value
Speed Act
(5.05)
is
equal or greater
than value of parameter
Speed Level 1 / 2 (5.16 / 5.17)
. The permitted
hysteresis is -0,78% (1/128) of parameter
Max Speed
(1.06)
. That means during rising speed the threshold
is exactly the value of
Speed Level 1 / 2 (5.16 / 5.17)
,
during falling speed the threshold is
Speed Level 1 /
2 (5.16 / 5.17) – 0,78%
. Signals
Speed > Lev1 /
Speed > Lev2
are independent on ON and RUN
command.
n
t
5DPS,Q$FW
6SHHG$FW
Ramp In Act +1,56% of
Max Speed (1.06)
speed ref
$W6HW3RLQW
At Set Point = 0
At Set Point = 0
Ramp In Act -1,56% of
Max Speed (1.06)
At Set Point
Speed Act (5.05)
Ramp In Act (5.33)
Comp
I1
I2
I1=I2
Signal "Overtemp Mot" / "Overtemp DCS"
in case of Alarm
Signal "Comm Fault"
If
Cmd Location (2.02) = Bus
the drive will trip in case
of fault
F20- Communication Fault
and will stop in
accordance to
Comm Fault Mode (2.07)
. If
Cmd
Location (2.02) = Makro depend
or
Terminals
or
Key
only an alarm
A11-Comm Interrupt
will be
shown and the drive will
not
trip.
n
t
Comp
I1
I2
I1=I2
6SHHG$FW
Speed > Lev 1/2
Speed Act (5.05)
Speed Level 1/2
(5.16/5.17)
Speed
Level 1
(5.16)
Speed
Level 2
(5.17)
Hysteresis = 0,78%
= Max Speed
(1.06) / 128
Hysteresis = 0,78%
= Max Speed
(1.06) / 128
6SHHG!/HY
6SHHG!/HY
6SHHG!/HY
6SHHG!/HY
PTC (DCS / Motor-AI2)
Digital Output DOx
Overtemp Mot/Overtemp DCS
$ODUP$RU$
A4-Converter Temp:high
A5-Motor Temp high
Fan On
PTC (DCS / Motor-AI2)
)DXOW)RU)
F7-Converter Overtemp
F8-Motor Overtemp
Reset
Fan On
Drive trips
Digital Output DOx
Overtemp Mot/Overtemp DCS
ok
ok
Fault
F20-Communication
Reset
Communication
faulty
Digital Output DOx
Comm Fault
Signal "Overtemp Mot" / "Overtemp DCS"
in case of Fault
Summary of Contents for DCS 400
Page 24: ...II K 3 14 Technical data ...
Page 29: ...II K 4 5 Overview of Software ...
Page 158: ...II K 6 36 Operating Instructions ...
Page 181: ...II K B 1 Appendix B Declaration of conformity ...
Page 190: ...Notices ...
Page 191: ...Notices ...