![ABB DCS 400 Manual Download Page 100](http://html.mh-extra.com/html/abb/dcs-400/dcs-400_manual_3327100.webp)
II K 4-76
Overview of Software
ParNo.
Parameter name and significance
Min
Max
Default
Unit
(1)
custom.
setting
Grp 9
Macro Adaptation (continued)
9.19
Disable Bridge1
Bridge 1 will be controlled from binary signal which is
assigned in this parameter.
Assignment identical with 9.05
State of binary signal:
0= Enable Bridge 1
1= Disable Bridge 1. Set affected Torque Ref to zero.
0
10
0
Text
x
9.20
Disable Bridge2
Bridge 2 will be controlled from binary signal which is
assigned in this parameter.
Assignment identical with 9.05
State of binary signal:
0= Enable Bridge 2
1= Disable Bridge 2. Set affected Torque Ref to zero.
0
10
0
Text
x
(1) no changes possible if the drive is in ON-status
Summary of Contents for DCS 400
Page 24: ...II K 3 14 Technical data ...
Page 29: ...II K 4 5 Overview of Software ...
Page 158: ...II K 6 36 Operating Instructions ...
Page 181: ...II K B 1 Appendix B Declaration of conformity ...
Page 190: ...Notices ...
Page 191: ...Notices ...