manualshive.com logo in svg
background image

HPV1000-App_Note_27 

 

 
 
 
 

HPV1000-App_Note_27 

Closed Loop Start Guide 

(Using the JVOP180 Keypad) 

Guide to set up HPV1000 drive in Closed Loop Vf Control 

 

 

 
 

 
 

 

 

Содержание HPV1000 Series

Страница 1: ...HPV1000 App_Note_27 HPV1000 App_Note_27 Closed Loop Start Guide Using the JVOP180 Keypad Guide to set up HPV1000 drive in Closed Loop Vf Control...

Страница 2: ...erfaces it is recommended that the parameters in the drive be set to what is recommended by the elevator controller in their technical manual Closed Loop Operation Set up 1 Enter verify that the drive...

Страница 3: ...Hoistway Parameter Set up 4 Enter verify the following parameters CONTRACT CAR SPD O1 25 parameter should be the lift contract speed in m s This can be verified with a hand tachometer if required and...

Страница 4: ...has several options for autotuning the motor however usually the motor will be roped and so the Tune No Rotate1 Static method will be used If the ropes are off and the motor can turn freely the Standa...

Страница 5: ...F1 05 between Forwards and Reverse Verify proper hoistway direction This can be reversed by changing both the MOTOR ROTATION B1 14 and ENCODER CONNECT F1 20 parameters Key Drive Parameters NOTE Key p...

Страница 6: ...e while idle Can be monitored in the D2 menu PWM FREQUENCY C6 03 Carrier frequency 8 kHz Setting this parameter to 8kHz is a good starting value to ensure low motor noise Increasing this value will de...

Страница 7: ...n Closed Loop Vect V f Control Open Loop Vector Closed Loop Vector PM ClosedLoop Vct Set to Closed Loop Vect Note not PM ClosedLoop Vct to run in Closed Loop mode Can be set to Open Loop Vect to run w...