168 Parameters
-30000 … 30000
rpm
High limit for critical speed 2.
1 = 1 rpm
25.06
Crit speed3 lo
Defines the low limit for critical speed range 3.
Note:
This value must be less than or equal to the value of
-30000 … 30000
rpm
Low limit for critical speed 3.
1 = 1 rpm
25.07
Crit speed3 hi
Defines the high limit for critical speed range 3.
Note:
This value must be greater than or equal to the value of
-30000 … 30000
rpm
High limit for critical speed 3.
1 = 1 rpm
26
26 Constant speeds
Constant speed selection and values. An active constant
speed overrides the drive speed reference. See section
on page
26.01
Const speed func
Determines how constant speeds are selected, and whether
the rotation direction signal is considered or not when
applying a constant speed.
26.02
Const speed sel1
When bit 0 of parameter
is 0
(Separate), selects a source that activates constant speed 1.
When bit 0 of parameter
is 1
(Packed), this parameter and parameters
select three sources whose
states activate constant speeds as follows:
DI1
Digital input DI1 (as indicated by
, bit 0).
1073742337
No.
Name/Value
Description
FbEq
Bit
Name
Information
0
Const speed
mode
1 = Packed: 7 constant speeds are selectable using the three sources
defined by parameters
0 = Separate: Constant speeds 1, 2 and 3 are separately activated by
the sources defined by parameters
and
respectively.
In case of conflict, the constant speed with the smaller number takes
priority.
1
Dir ena
1 = Start dir: To determine running direction for a constant speed, the
sign of the constant speed setting (parameters
) is
multiplied by the direction signal (forward: +1, reverse: -1). For example,
if the direction signal is reverse and the active constant speed is
negative, the drive will run in the forward direction.
0 = Accord Par: The running direction for the constant speed is
determined by the sign of the constant speed setting (parameters
).
Source defined
by par.
Source defined
by par.
Constant speed active
0
0
0
None
1
0
0
Constant speed 1
0
1
0
Constant speed 2
1
1
0
Constant speed 3
0
0
1
Constant speed 4
1
0
1
Constant speed 5
0
1
1
Constant speed 6
1
1
1
Constant speed 7
Summary of Contents for ACS850-04 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Page 4: ......
Page 10: ...10 Table of contents...
Page 52: ...52 The ACS850 control panel...
Page 56: ...56 Control locations and operating modes...
Page 80: ...80 Program features...
Page 236: ...236 Parameters...
Page 286: ...286 Fieldbus control...
Page 294: ...294 Control block diagrams...